Increasing EDV Range through Intelligent Cabin Air Handling Strategies: Annual Progress Report
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
Computational fluid dynamics (CFD) simulations of a Ford Focus Electric demonstrated that a split flow heating, ventilating and air conditioning (HVAC) system with rear recirculation ducts can reduce cabin heating loads by up to 57.4% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Simulations also showed that implementing a continuous recirculation fraction control system into the original equipment manufacturer (OEM) HVAC system can reduce cabin heating loads by up to 50.0% relative to full fresh air usage under some conditions (steady state, four passengers, ambient temperature of -5 deg C). Identified that continuous fractional recirculation control of the OEM system can provide significant energy savings for EVs at minimal additional cost, while a split flow HVAC system with rear recirculation ducts only provides minimal additional improvement at significant additional cost.
- Research Organization:
- National Renewable Energy Lab. (NREL), Golden, CO (United States)
- Sponsoring Organization:
- USDOE Office of Energy Efficiency and Renewable Energy (EERE), Vehicle Technologies Office (EE-3V)
- DOE Contract Number:
- AC36-08GO28308
- OSTI ID:
- 1293807
- Report Number(s):
- NREL/MP-5400-65054
- Country of Publication:
- United States
- Language:
- English
Similar Records
Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design
Aircraft skin cooling system for thermal management of onboard high power electronic equipment