skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Booster Double Harmonic Setup Notes

Technical Report ·
DOI:https://doi.org/10.2172/1172091· OSTI ID:1172091
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

The motivation behind implementing a booster double harmonic include the reduced transverse space charge force from a reduced peak beam current and reduced momentum spread of the beam, both of which can be achieved from flattening the RF bucket. RF capture and acceleration of polarized protons (PP) is first set up in the single harmonic mode with RF harmonic h=1. Once capture and acceleration have been set up in the single harmonic mode, the second harmonic system is brought on and programmed to operate in concert with the single harmonic system.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP)
DOE Contract Number:
SC0012704
OSTI ID:
1172091
Report Number(s):
BNL-107525-2015-IR; BNL-C-A/AP/535; R&D Project: KBCH139; 18031; KB0202011; TRN: US1500138
Country of Publication:
United States
Language:
English