Title: Comments on Injector Proton Beam Study in Run 2014

Technical Report ·
DOI:https://doi.org/10.2172/1162167· OSTI ID:1162167
 [1]
  1. Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

During the entire period of injector proton study in run 2014, it seems that the beam transverse emittance out of Booster is larger than that in run 2013. The emittance measured at the BtA transfer line and also the transmission from Booster late to AGS late are presented for this argument. In addition to this problem, it seems that the multiturn Booster injection, which defines the transverse emittance, needs more attention. Moreover, for high intensity operations, the space charge effect may be already relevant in RHIC polarized proton runs. With the RHIC proton intensity improvement in the next several years, higher Booster input intensity is needed, therefore, the space charge effect at the Booster injection and early ramp may become a new limiting factor.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States). Alternating Gradient Synchrotron
Sponsoring Organization:
USDOE Office of Science (SC), Nuclear Physics (NP)
DOE Contract Number:
AC02-98CH10886
OSTI ID:
1162167
Report Number(s):
BNL-106264-2014-IR; BNL-C-A/AP/530; R&D Project: KBCH139; KB0202011; TRN: US1500126
Country of Publication:
United States
Language:
English

Similar Records

Booster and AGS transverse emittance during the 2006 and 2009 polarized proton runs
Technical Report · Wed Sep 01 00:00:00 EDT 2010 · OSTI ID:1162167

RHIC Au beam in Run 2014
Technical Report · Mon Sep 15 00:00:00 EDT 2014 · OSTI ID:1162167

The 2022 Polarized Proton Run in the Injectors
Technical Report · Mon Oct 17 00:00:00 EDT 2022 · OSTI ID:1162167