Title: Case Study of the Maplewood Park Multifamily Retrofit for Energy Efficiency

Technical Report ·
DOI:https://doi.org/10.2172/1122647· OSTI ID:1122647
 [1];  [1];  [1];  [2];  [2]
  1. Southface Energy Inst., Atlanta, GA (United States)
  2. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

Maplewood Park (Maplewood), a 110-unit multifamily apartment complex in Union City, Georgia, completed major renovations under the guidance of a third-party green building certification program in October 2012. Oak Ridge National Laboratory (ORNL) partnered with Southface Energy Institute (Southface) to use this project as a case study of energy retrofits in low-rise, garden-style, multifamily buildings in the southeastern United States. This report provides a comprehensive profile of this project including the project economics, findings of the building audit, and results of the analysis of energy retrofit measures specific to this project. With a main focus of energy retrofits, this report aims to discuss other aspects of multifamily building retrofit that would benefit future projects in terms of improved building audit process, streamlined tasks, and higher energy savings in low-rise, garden-style apartments. Maplewood received Low Income Housing Tax Credit (LIHTC) financing via the 2010 Georgia Qualified Allocation Plan (QAP). To be eligible for QAP funds in Georgia, all major renovations must incorporate energy-efficiency measures and adopt a third-party green building certification. Because of the unique demands of this financing, including requirements for long-term ownership, property owners were also especially motivated to invest in upgrades that will increase durability and comfort while reducing the energy cost for the tenants.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-00OR22725
OSTI ID:
1122647
Report Number(s):
ORNL/TM-2012/592
Country of Publication:
United States
Language:
English

Similar Records

Building America Case Study: Rehabilitation of USDA Multifamily Homes, Georgia (Climate Zones 2-4)
Program Document · Fri Apr 01 00:00:00 EDT 2016 · OSTI ID:1122647

Multifamily Housing Rehabilitation Process Improvements
Technical Report · Tue Mar 01 00:00:00 EST 2016 · OSTI ID:1122647

Need for Systematic Retrofit Analysis in Multifamily Buildings
Conference · Wed Jan 01 00:00:00 EST 2014 · OSTI ID:1122647

Related Subjects