Title: Cryogenic vertical test facility for the SRF cavities at BNL

Conference ·
OSTI ID:1012592

A vertical test facility has been constructed to test SRF cavities and can be utilized for other applications. The liquid helium volume for the large vertical dewar is approximate 2.1m tall by 1m diameter with a clearance inner diameter of 0.95m after the inner cold magnetic shield installed. For radiation enclosure, the test dewar is located inside a concrete block structure. The structure is above ground, accessible from the top, and equipped with a retractable concrete roof. A second radiation concrete facility, with ground level access via a labyrinth, is also available for testing smaller cavities in 2 smaller dewars. The cryogenic transfer lines installation between the large vertical test dewar and the cryo plant's sub components is currently near completion. Controls and instrumentations wiring are also nearing completion. The Vertical Test Facility will allow onsite testing of SRF cavities with a maximum overall envelope of 0.9 m diameter and 2.1 m height in the large dewar and smaller SRF cavities and assemblies with a maximum overall envelope of 0.66 m diameter and 1.6 m height.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Organization:
DOE - Office Of Science
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1012592
Report Number(s):
BNL-94152-2011-CP; R&D Project: KBCH139; 18039; KB0202011; TRN: US1102334
Resource Relation:
Conference: 2011 Particle Accelerator Conference (PAC'11); New York, NY; 20110328 through 20110401
Country of Publication:
United States
Language:
English

Similar Records

SRF CAVITY PERFORMANCE OVERVIEW FOR THE 12 GeV UPGRADE
Conference · Sun Jul 01 00:00:00 EDT 2012 · OSTI ID:1012592

Camera assembly design proposal for SRF cavity image collection
Technical Report · Mon Oct 10 00:00:00 EDT 2011 · OSTI ID:1012592

Cryogenic system for the Energy Recovery Linac and vertical test facility at BNL
Conference · Mon Mar 28 00:00:00 EDT 2011 · OSTI ID:1012592