skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Operation and performance of the silicon vertex detector (SVX`) at CDF

Conference ·
OSTI ID:10103039
 [1]
  1. Univ. of Pittsburgh, PA (United States). Dept. of Physics and Astronomy

The authors describe the operation and performance of the Silicon Vertex Detector (SVX`), which replaced the CDF SVX detector for run lb of the Fermilab Tevatron Collider. The new features of the SVX` include AC coupled readout, Field OXide Field Effect Transistor (FOXFET) biasing and radiation hard front end electronics. The authors expect the detector to survive beyond the 100 pb{sup -1} of data taking anticipated for the present CDF physics run. Preliminary results from the collider data show that the detector has a resolution of about 12 {mu}m. This provides a powerful tool to do top and bottom physics.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
10103039
Report Number(s):
FNAL/C-94/352-E; CONF-940816-60; ON: DE95003380; TRN: 95:000333
Resource Relation:
Conference: 8. meeting Division of Particles and Fields of the American Physical Society,Albuquerque, NM (United States),2-6 Aug 1994; Other Information: PBD: Oct 1994
Country of Publication:
United States
Language:
English