skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The IFR Online Detector Control system at the BaBar Experiment

Technical Report ·
DOI:https://doi.org/10.2172/10095· OSTI ID:10095

The Instrumented Flux Return (IFR)[1] is one of the five subdetectors of the BaBar[2] experiment on the PEP II accelerator at SLAC. The IFR consists of 774 Resistive Plate Chamber (RPC) detectors, covering an area of about 2,000 m{sup 2} and equipped with 3,000 Front-end Electronic Cards (FEC) reading about 50,000 channels (readout strips). The first aim of a B-factory experiment is to run continuously without any interruption and then the Detector Control system plays a very important role in order to reduce the dead-time due to the hardware problems. The I.N.F.N. group of Naples has designed and built the IFR Online Detector Control System (IODC)[3] in order to control and monitor the operation of this large number of detectors and of all the IFR subsystems: High Voltage, Low Voltage, Gas system, Trigger and DAQ crates. The IODC consists of 8 custom DAQ stations, placed around the detector and one central DAQ station based on VME technology and placed in electronic house. The IODC use VxWorks and EPICS to implement slow control data flow of about 2500 hardware channels and to develop part of the readout module consisting in about 3500 records. EPICS is interfaced with the BaBar Run Control through the Component Proxy and with the BaBar database (Objectivity) through the Archiver and KeyLookup processes.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC03-76SF00515
OSTI ID:
10095
Report Number(s):
SLAC-PUB-8167; TRN: US0103357
Resource Relation:
Other Information: PBD: 7 Jul 1999
Country of Publication:
United States
Language:
English

Similar Records

The BaBar LST Detector High Voltage System: Design And Implementation
Conference · Fri Aug 18 00:00:00 EDT 2006 · IEEE Nucl.Sci.Symp.Conf.Rec.2:1145-1148,2006 · OSTI ID:10095

Development of a Data Acquisition System for the BaBar CP Violation Experiment
Technical Report · Tue Jun 22 00:00:00 EDT 1999 · OSTI ID:10095

DATA ACQUISITION FOR SNS BEAM LOSS MONITOR SYSTEM
Conference · Mon Oct 13 00:00:00 EDT 2003 · OSTI ID:10095