skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: A Study of undulator magnets characterization using the Vibrating Wire technique

Technical Report ·
DOI:https://doi.org/10.2172/1004931· OSTI ID:1004931

The vibrating wire (VW) technique employs a stretched wire as a magnetic field sensor. Because of the wire's small diameter ({approx}0.1mm or smaller) and because the wire can be supported from outside the magnet, this technique is very appealing for field measurements in small gap/bore undulators with small good field regions and with limited access to the tested field. In addition, in the case of elliptical undulators in which Hall probe (HP) measurements can be affected by the planar Hall effect, VW technique can be used as an independent method to verify and supplement HP measurements. In this article we studied the potential of the VW technique for measurement of magnetic field errors and for prediction of beam trajectories in undulator magnets using a 3.8m long LCLS undulator as a test bench. Introducing calibrated magnetic field distortion at various locations, we measured the sensitivity and spatial resolution of the method. The method demonstrated 0.9mm spatial resolution at a distance up to a few meters and 0.37Gcm sensitivity to the field integral. To compare Hall probe and Vibrating wire measurements side-by-side, we measured field errors in an LCLS undulator previously characterized by Hall probe measurements. The field errors found with the Vibrating Wire technique appeared to be in good agreement with errors measured with the Hall probe. Beam trajectory distortions calculated from both data sets are also in a good agreement.

Research Organization:
SLAC National Accelerator Lab., Menlo Park, CA (United States)
Sponsoring Organization:
USDOE Office of Science (SC)
DOE Contract Number:
AC02-76SF00515
OSTI ID:
1004931
Report Number(s):
SLAC-TN-10-027; TRN: US1101061
Country of Publication:
United States
Language:
English

Similar Records

MAGNETIC MEASUREMENT SYSTEM FOR THE NSLS SUPERCONDUCTING UNDULATOR VERTICAL TEST FACILITY.
Conference · Mon May 16 00:00:00 EDT 2005 · OSTI ID:1004931

Stability of the LCLS Undulator Hall
Technical Report · Mon Jan 31 00:00:00 EST 2005 · OSTI ID:1004931

Algorithms to Automate LCLS Undulator Tuning
Technical Report · Fri Dec 03 00:00:00 EST 2010 · OSTI ID:1004931