skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Predicting susceptibility of alloy 600 to intergranular stress corrosion cracking using a modified electrochemical potentiokinetic reactivation test

Journal Article · · Corrosion
DOI:https://doi.org/10.5006/1.3293610· OSTI ID:72872
;  [1];  [2]
  1. Korea Advanced Inst. of Science and Technology, Taejon (Korea, Republic of). Dept. of Materials Science and Engineering
  2. Korea Inst. of Nuclear Safety, Taejon (Korea, Republic of). Policy and Planning Dept.

Modified double-loop electrochemical potentiokinetic reactivation (DL-EPR) tests were applied to evaluate the degree of sensitization (DOS) for alloy 600 aged at 700 C. Results of the modified DL-EPR test were compared to intergranular stress corrosion cracking (IGSCC) susceptibilities determined in deaerated 0.01 M sodium tetrathionate under deformation at a constant strain rate of 0.93 {times} 10{sup {minus}6}/s. By analyzing the effects of solution concentration, temperature, and scan rate on the electrochemical response in the EPR tests and the morphologies, the optimal modified DL-EPR test condition for alloy 600 was obtained in 0.01 M sulfuric acid + 10 ppm potassium thiocyanate at 25 C and at a scan rate of 0.5 mV/s. The standard DL-EPR test, performed under conditions of 0.5 M H{sub 2}SO{sub 4} + 0.01 M KCNS at 30 C and a scan rate of 1.67 mV/s, provided very poor discriminating power for various DOS of alloy 600 because general and pitting corrosion occurred, in addition to intergranular corrosion. The modified test, however, was highly discriminating because of its highly selective corrosion attack at grain boundaries. IGSCC occurred in samples of alloy 600 aged for < 20 h, and susceptibility to IGSCC{sub s} increased with decreasing aging times up to 1 h, showing maximum IGSCC{sub s} in the sample aged for 1 h. IGSCC{sub s} for the alloy was found to be associated closely with the chromium-depleted profile across grain boundaries. The deeper and narrower chromium-depleted zone produced greater IGSCC{sub s}. It was demonstrated that DOS measured by the modified DL-EPR test was correlated more closely with IGSCC{sub s} than was DOS measured by the standard EPR test. This correlation resulted from the fact that the modified EPR test selectively attacked the more deeply chromium-depleted regions in comparison to the standard EPR test.

Sponsoring Organization:
USDOE
OSTI ID:
72872
Journal Information:
Corrosion, Vol. 51, Issue 6; Other Information: PBD: Jun 1995
Country of Publication:
United States
Language:
English