Title: The dynamics of a turbine-driven reactor feedwater pump and identification of related parameters in the Kuosheng power station

Journal Article · · Nuclear Technology; (United States)
OSTI ID:6169443
;  [1];  [2]
  1. Inst. of Nuclear Research, Taoyuan (Taiwan, Province of China)
  2. Taiwan Power Co., Taipei (Taiwan, Province of China)

In the Kuosheng nuclear power station, a turbine-driven reactor feedwater pump (TDRFP) is used to drive feedwater to the reactor pressure vessel (RPV). The performance of the TDRFP plays an important role in the safe operation of the nuclear power station as it governs the water inventory in the RPV. The dynamics of the TDRFP in the Kuosheng nuclear power station are simulated, and related parameters are identified by the simplex search method. A reactor feedwater pump (RFP) trip test was performed during the startup test of the Kuosheng nuclear power station. This RFP trip transient was selected for this study because it simplifies the identification process. The ratio of rated torque to moments of inertia, parameters related to the characteristic H-Q curve, and parameters related to the characteristic T-Q curve are verified.

OSTI ID:
6169443
Journal Information:
Nuclear Technology; (United States), Vol. 103:3; ISSN 0029-5450
Country of Publication:
United States
Language:
English