Watts nickel and rinse water recovery via an advanced reverse osmosis system
The report summarizes the results of an eight month test program conducted at the Hewlett Packard Printed Circuit Board Production Plant, Sunnyvale, CA (H.P.) to assess the effectiveness of an advanced reverse osmosis system (AROS). The AROS unit, manufactured by Water Technologies, Inc. (WTI) of Minneapolis, MN, incorporates membrane materials and system components designed to treat metal plating rinse water and produce two product streams; (1) a concentrated metal solution suitable for the plating bath, and (2) rinse water suitable for reuse as final rinse. Waste water discharge can be virtually eliminated and significant reductions realized in the need for new plating bath solution and rinse water.
- Research Organization:
- Science Applications International Corp., Santa Ana, CA (United States)
- OSTI ID:
- 5915848
- Report Number(s):
- PB-93-229011/XAB; CNN: EPA-68-C8-0062
- Resource Relation:
- Other Information: See also PB--266-919
- Country of Publication:
- United States
- Language:
- English
Similar Records
Reverse osmosis in the metal finishing industry
Evaporator concentrates plating rinse for recycle to process
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
INDUSTRIAL WASTES
WATER POLLUTION ABATEMENT
WASTE WATER
RECYCLING
COST ESTIMATION
ELECTROPLATING
MANUFACTURING
MATERIALS RECOVERY
NICKEL
OSMOSIS
TECHNOLOGY ASSESSMENT
TECHNOLOGY TRANSFER
WATER POLLUTION CONTROL
CONTROL
DEPOSITION
DIFFUSION
ELECTRODEPOSITION
ELECTROLYSIS
ELEMENTS
HYDROGEN COMPOUNDS
LIQUID WASTES
LYSIS
MANAGEMENT
METALS
OXYGEN COMPOUNDS
PLATING
POLLUTION ABATEMENT
POLLUTION CONTROL
PROCESSING
SURFACE COATING
TRANSITION ELEMENTS
WASTE MANAGEMENT
WASTE PROCESSING
WASTES
WATER
540320* - Environment
Aquatic- Chemicals Monitoring & Transport- (1990-)
320305 - Energy Conservation
Consumption
& Utilization- Industrial & Agricultural Processes- Industrial Waste Management