skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Energy conservation at The University of Miami

Conference ·
OSTI ID:54718

The University of Miami (UM) has embarked on a very important and worthwhile mission: {open_quotes}To make UM one of the most energy efficient Universities in the Nation by the year 2000.{close_quotes} In order for the University to meet this goal we knew we would need to take advantage of all the available technologies and address the freon issues. In June 1990 the Coral Gables Campus had five chilled Water Production Plants, each representing small independent systems serving from four to ten buildings. Because of energy conservation measures of the past (i.e. elimination, reheat, first generation lighting retrofits, and some diversity), each plant had excess capacity. At that time we also had identified about 600 tons of old falling apart air conditioning equipment. Our Capital Construction Program was beginning design efforts for a new Music Recital Hall and an addition to the Law Library. With all this considered it made sense to develop a common chilled water loop to connect these plants and provide a vehicle to capitalize on available capacity. As this concept took shape it became evident that a master chilled water loop encircling the entire campus would address the next 20 years of campus development. This 20 year plan would require various phases of development. Phase I would connect three chilled water production plants and enable us to supply chilled water to seven existing facilities with approximately 600 tons of old inefficient air conditioning equipment and supply chilled water to the new Law and Music facilities, (approximately 400 tons) without buying any additional chillers.

OSTI ID:
54718
Report Number(s):
CONF-941218-; TRN: 95:003625-0026
Resource Relation:
Conference: 17. world energy engineering congress and the 4th environmental technology congress and expo, Atlanta, GA (United States), 7-9 Dec 1994; Other Information: PBD: 1995; Related Information: Is Part Of Competitive energy management and environmental technologies: Proceedings; PB: 640 p.
Country of Publication:
United States
Language:
English

Similar Records

Energy efficiency at the University of Miami
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · Strategic Planning for Energy and the Environment · OSTI ID:54718

Energy analysis for retrofit of chilled water plants
Journal Article · Sat Jun 01 00:00:00 EDT 1996 · Energy Engineering · OSTI ID:54718

Institutional project summary University of Redlands direct fired gas absorption chiller system
Conference · Wed May 01 00:00:00 EDT 1996 · OSTI ID:54718