Title: Brachial artery vasomotion and transducer pressure effect on measurements by active contour segmentation on ultrasound

Journal Article · · Medical Physics
DOI:https://doi.org/10.1118/1.4862508· OSTI ID:22251640
; ; ;  [1]
  1. Department of Medicine, Division of Cardiovascular Medicine, Section of Vascular Medicine, Perelman School of Medicine, University of Pennsylvania, Philadelphia, Pennsylvania 19104 (United States)

Purpose: To use feed-forward active contours (snakes) to track and measure brachial artery vasomotion on ultrasound images recorded in both transverse and longitudinal views; and to compare the algorithm's performance in each view. Methods: Longitudinal and transverse view ultrasound image sequences of 45 brachial arteries were segmented by feed-forward active contour (FFAC). The segmented regions were used to measure vasomotion artery diameter, cross-sectional area, and distention both as peak-to-peak diameter and as area. ECG waveforms were also simultaneously extracted frame-by-frame by thresholding a running finite-difference image between consecutive images. The arterial and ECG waveforms were compared as they traced each phase of the cardiac cycle. Results: FFAC successfully segmented arteries in longitudinal and transverse views in all 45 cases. The automated analysis took significantly less time than manual tracing, but produced superior, well-behaved arterial waveforms. Automated arterial measurements also had lower interobserver variability as measured by correlation, difference in mean values, and coefficient of variation. Although FFAC successfully segmented both the longitudinal and transverse images, transverse measurements were less variable. The cross-sectional area computed from the longitudinal images was 27% lower than the area measured from transverse images, possibly due to the compression of the artery along the image depth by transducer pressure. Conclusions: FFAC is a robust and sensitive vasomotion segmentation algorithm in both transverse and longitudinal views. Transverse imaging may offer advantages over longitudinal imaging: transverse measurements are more consistent, possibly because the method is less sensitive to variations in transducer pressure during imaging.

OSTI ID:
22251640
Journal Information:
Medical Physics, Vol. 41, Issue 2; Other Information: (c) 2014 American Association of Physicists in Medicine; Country of input: International Atomic Energy Agency (IAEA); ISSN 0094-2405
Country of Publication:
United States
Language:
English

Similar Records

Dose Constraints to Prevent Radiation-Induced Brachial Plexopathy in Patients Treated for Lung Cancer
Journal Article · Thu Mar 01 00:00:00 EST 2012 · International Journal of Radiation Oncology, Biology and Physics · OSTI ID:22251640

Occluded Brescia-Cimino Hemodialysis Fistulas: Endovascular Treatment with Both Brachial Arterial and Venous Access Using the Pull-Through Technique
Journal Article · Thu Dec 15 00:00:00 EST 2005 · Cardiovascular and Interventional Radiology · OSTI ID:22251640

Use of a Collagen-Based Device for Closure of Low Brachial Artery Punctures
Journal Article · Sun Apr 15 00:00:00 EDT 2007 · Cardiovascular and Interventional Radiology · OSTI ID:22251640