Estimates of radiation absorbed doses from radionuclides internally deposited in a pregnant woman and her fetus are very important due to elevated fetal radiosensitivity. This paper reports a set of specific absorbed fractions (SAFs) for use with the dosimetry schema developed by the Society of Nuclear Medicine's Medical Internal Radiation Dose (MIRD) Committee. The calculations were based on three newly constructed pregnant female anatomic models, called RPI-P3, RPI-P6, and RPI-P9, that represent adult females at 3-, 6-, and 9-month gestational periods, respectively. Advanced Boundary REPresentation (BREP) surface-geometry modeling methods were used to create anatomically realistic geometries and organ volumes that were carefully adjusted to agree with the latest ICRP reference values. A Monte Carlo user code, EGS4-VLSI, was used to simulate internal photon emitters ranging from 10 keV to 4 MeV. SAF values were calculated and compared with previous data derived from stylized models of simplified geometries and with a model of a 7.5-month pregnant female developed previously from partial-body CT images. The results show considerable differences between these models for low energy photons, but generally good agreement at higher energies. These differences are caused mainly by different organ shapes and positions. Other factors, such as the organ mass, the source-to-target-organ centroid distance, and the Monte Carlo code used in each study, played lesser roles in the observed differences in these. Since the SAF values reported in this study are based on models that are anatomically more realistic than previous models, these data are recommended for future applications as standard reference values in internal dosimetry involving pregnant females.
- OSTI ID:
- 21120852
- Journal Information:
- Medical Physics, Journal Name: Medical Physics Journal Issue: 7 Vol. 35; ISSN 0094-2405; ISSN MPHYA6
- Country of Publication:
- United States
- Language:
- English
Similar Records
Development of a series of Korean pediatric and adult head computational phantoms and application to nuclear medicine dosimetry - Paper 26
WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry
Effect of respiratory motion on internal radiation dosimetry
Conference
·
Mon Sep 15 00:00:00 EDT 2014
·
OSTI ID:23082873
WE-H-207A-07: Image-Based Versus Atlas-Based Internal Dosimetry
Journal Article
·
Wed Jun 15 00:00:00 EDT 2016
· Medical Physics
·
OSTI ID:22679167
Effect of respiratory motion on internal radiation dosimetry
Journal Article
·
Sat Nov 01 00:00:00 EDT 2014
· Medical Physics
·
OSTI ID:22318087