Title: X-ray absorption fine structure measurement with a 9 V electric battery x-ray emitter

Journal Article · · Applied Physics Letters
DOI:https://doi.org/10.1063/1.2356462· OSTI ID:20860939
; ; ;  [1]
  1. Department of Materials Science and Engineering, Kyoto University, Sakyo-ku, Kyoto 606-8501 (Japan)

X-ray absorption spectral analysis is a well known technique for analyzing the chemical environment of an element in a specimen. It has been believed that high intensity and monochromatized x rays such as the synchrotron radiation are required for an x-ray absorption experiment. In the present study, however, we demonstrate that the x-ray absorption spectral measurement of transition metal foils with an energy resolution of 10 eV is possible with a combination of a 9 V dry electric battery pyroelectric x-ray generator and a superconducting microcalorimeter.

OSTI ID:
20860939
Journal Information:
Applied Physics Letters, Vol. 89, Issue 13; Other Information: DOI: 10.1063/1.2356462; (c) 2006 American Institute of Physics; Country of input: International Atomic Energy Agency (IAEA); ISSN 0003-6951
Country of Publication:
United States
Language:
English