DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Wearable Sensor Application for Integrated Early Warning and Health Surveillance

Abstract

Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health using physiologic and environmental indicators. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and landscape data, and calculates the corresponding physiological strain index. The information is presented to the analyst in a group and individual view with real-time alerting of abnormal health parameters. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agency's Biosurveillance Ecosystem (BSVE).Introduction: Wearable devices are a low cost, minimally invasive way to monitor health. Sensor data provides real-time physiological indictors of an individual’s health status without the requirement of health care professionals or facilities. Information gleamed from wearable sensors can be used to better understand physiological stressors and prodromal symptoms. In addition, this data can be used to monitor individuals that are in high risk of health-related problems.However, raw data from wearable sensors can be overwhelming to process and laborious to monitor for an individual and, even more so, for a group of individuals. Often specific combination of ranges of sensor readings are indicativemore » of changes to health status and need to be evaluated together or used to calculate specific signal parameters. In addition, the environment surrounding the individual needs to be considered when interpreting the data. To address these issues, PNNL has developed an application that collects, analyzes, and integrates wearable sensor data with geographic landscape and weather information to provide a real-time early alert and situational awareness tool for monitoring the health of groups and individuals.Methods: The prototype application described here was a product of PNNL’s BSVE Application Development Competition. The final product that will be deployed in the BSVE is currently under development by PNNL and will vary slightly in the exact design and architecture described.Data. Wearable sensor data was collected from the Rim2Rim (R2R) Watch Study of individuals hiking the Grand Canyon in Arizona [1]. Weather information was obtained from nearby weather stations and mapping features were derived from Google Maps.Calculations. A physiological Strain Index (PSI) was calculated using core temperature estimates derived through a Kalman Filter approach and heart rate [2,3].Application. The prototype backend application development was based in Python with a MongoDB. The front-end development was built using a scalable architecture and modular approach with components in React and D3.Results: A prototype application was developed this past summer through the PNNL BSVE App Competition (Fig 1). The application was aimed at visualizing wearable sensor data from the Grand Canyon R2R hike dataset. Simulated real-time analysis was used to calculate health status of individuals hiking based on measured physiological parameters and to alert to individuals with signs of physiologic health stress. Visualization tools were incorporated to enable sensor data for individuals and the group to be viewed simultaneously along with pertinent weather, geographic, and elevation data.Many features described in the prototype application will be incorporated into the final BSVE application. The key changes will be 1) the ability to select given time periods for viewing historical data as well as the real-time data collection, 2) environmental data and map view will come from BSVE internal data sources, and 3) the alerts will provide more information and have their own page for reviewing.Conclusions: The Wearable Sensor Application developed by PNNL for integration into the BSVE provides an early warning system for individual and group health using physiologic and environmental parameters. The application highlights health status from wearable sensors and relevant environmental parameters while monitoring a calculated physiological strain index. With this tool, an analyst can easily monitor the health of individuals and groups with the aid of real-time alerting tool for early detection of abnormal health parameters.« less

Authors:
 [1];  [1];  [1];  [1];  [1];  [1];  [1]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States)
Publication Date:
Research Org.:
Pacific Northwest National Lab, Richland, WA (United States)
Sponsoring Org.:
USDOE Office of Science (SC); Defense Threat Reduction Agency (DTRA)
OSTI Identifier:
1629192
Grant/Contract Number:  
AC05-76RL01830; CB10190
Resource Type:
Accepted Manuscript
Journal Name:
Online Journal of Public Health Informatics
Additional Journal Information:
Journal Volume: 10; Journal Issue: 1; Journal ID: ISSN 1947-2579
Publisher:
University of Illinois at Chicago
Country of Publication:
United States
Language:
English
Subject:
Wearable Sensors; Health Surveillance; Early Warning; Real-time Data; Physiologic Strain Index

Citation Formats

Charles, Lauren E., Wright, Devin P., Huang, Zhuanyi, White, Cree, Anubhav, Fnu, Jin, Yuanqing, and Henry, Michael. Wearable Sensor Application for Integrated Early Warning and Health Surveillance. United States: N. p., 2018. Web. doi:10.5210/ojphi.v10i1.8552.
Charles, Lauren E., Wright, Devin P., Huang, Zhuanyi, White, Cree, Anubhav, Fnu, Jin, Yuanqing, & Henry, Michael. Wearable Sensor Application for Integrated Early Warning and Health Surveillance. United States. https://doi.org/10.5210/ojphi.v10i1.8552
Charles, Lauren E., Wright, Devin P., Huang, Zhuanyi, White, Cree, Anubhav, Fnu, Jin, Yuanqing, and Henry, Michael. Tue . "Wearable Sensor Application for Integrated Early Warning and Health Surveillance". United States. https://doi.org/10.5210/ojphi.v10i1.8552. https://www.osti.gov/servlets/purl/1629192.
@article{osti_1629192,
title = {Wearable Sensor Application for Integrated Early Warning and Health Surveillance},
author = {Charles, Lauren E. and Wright, Devin P. and Huang, Zhuanyi and White, Cree and Anubhav, Fnu and Jin, Yuanqing and Henry, Michael},
abstractNote = {Objective: The Wearable Sensor Application developed by Pacific Northwest National Laboratory (PNNL) provides an early warning system for stressors to individual and group health using physiologic and environmental indicators. The application integrates health monitoring parameters from wearable sensors, e.g., temperature and heart rate, with relevant environmental parameters, e.g., weather and landscape data, and calculates the corresponding physiological strain index. The information is presented to the analyst in a group and individual view with real-time alerting of abnormal health parameters. This application is the first of its kind being developed for integration into the Defense Threat Reduction Agency's Biosurveillance Ecosystem (BSVE).Introduction: Wearable devices are a low cost, minimally invasive way to monitor health. Sensor data provides real-time physiological indictors of an individual’s health status without the requirement of health care professionals or facilities. Information gleamed from wearable sensors can be used to better understand physiological stressors and prodromal symptoms. In addition, this data can be used to monitor individuals that are in high risk of health-related problems.However, raw data from wearable sensors can be overwhelming to process and laborious to monitor for an individual and, even more so, for a group of individuals. Often specific combination of ranges of sensor readings are indicative of changes to health status and need to be evaluated together or used to calculate specific signal parameters. In addition, the environment surrounding the individual needs to be considered when interpreting the data. To address these issues, PNNL has developed an application that collects, analyzes, and integrates wearable sensor data with geographic landscape and weather information to provide a real-time early alert and situational awareness tool for monitoring the health of groups and individuals.Methods: The prototype application described here was a product of PNNL’s BSVE Application Development Competition. The final product that will be deployed in the BSVE is currently under development by PNNL and will vary slightly in the exact design and architecture described.Data. Wearable sensor data was collected from the Rim2Rim (R2R) Watch Study of individuals hiking the Grand Canyon in Arizona [1]. Weather information was obtained from nearby weather stations and mapping features were derived from Google Maps.Calculations. A physiological Strain Index (PSI) was calculated using core temperature estimates derived through a Kalman Filter approach and heart rate [2,3].Application. The prototype backend application development was based in Python with a MongoDB. The front-end development was built using a scalable architecture and modular approach with components in React and D3.Results: A prototype application was developed this past summer through the PNNL BSVE App Competition (Fig 1). The application was aimed at visualizing wearable sensor data from the Grand Canyon R2R hike dataset. Simulated real-time analysis was used to calculate health status of individuals hiking based on measured physiological parameters and to alert to individuals with signs of physiologic health stress. Visualization tools were incorporated to enable sensor data for individuals and the group to be viewed simultaneously along with pertinent weather, geographic, and elevation data.Many features described in the prototype application will be incorporated into the final BSVE application. The key changes will be 1) the ability to select given time periods for viewing historical data as well as the real-time data collection, 2) environmental data and map view will come from BSVE internal data sources, and 3) the alerts will provide more information and have their own page for reviewing.Conclusions: The Wearable Sensor Application developed by PNNL for integration into the BSVE provides an early warning system for individual and group health using physiologic and environmental parameters. The application highlights health status from wearable sensors and relevant environmental parameters while monitoring a calculated physiological strain index. With this tool, an analyst can easily monitor the health of individuals and groups with the aid of real-time alerting tool for early detection of abnormal health parameters.},
doi = {10.5210/ojphi.v10i1.8552},
journal = {Online Journal of Public Health Informatics},
number = 1,
volume = 10,
place = {United States},
year = {Tue May 22 00:00:00 EDT 2018},
month = {Tue May 22 00:00:00 EDT 2018}
}

Works referenced in this record:

Estimation of human core temperature from sequential heart rate observations
journal, June 2013

  • Buller, Mark J.; Tharion, William J.; Cheuvront, Samuel N.
  • Physiological Measurement, Vol. 34, Issue 7
  • DOI: 10.1088/0967-3334/34/7/781

A physiological strain index to evaluate heat stress
journal, July 1998

  • Moran, Daniel S.; Shitzer, Avraham; Pandolf, Kent B.
  • American Journal of Physiology-Regulatory, Integrative and Comparative Physiology, Vol. 275, Issue 1
  • DOI: 10.1152/ajpregu.1998.275.1.r129