DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns

Abstract

The development of a tandem column purification method for the preparation of high-purity 89Zr(IV) oxalate is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of 33 μL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent solution for the primary column is equivalent to the 89Zr load solution for the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr(IV) oxalate. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1 ± 1.3% of the 89Zr present in the foils was recovered in the secondary columnmore » elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29 ± 0.06 mL (representing 86 ± 5% of the 89Zr activity in the target). This product volume represents a significant improvement in radionuclide product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 T Bq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. In conclusion, these ESA and [MB] values infer that the 89Zr(IV) oxalate product resulting from this tandem column isolation method has the highest purity reported to date.« less

Authors:
ORCiD logo [1];  [1];  [1];  [1];  [2]
  1. Pacific Northwest National Lab. (PNNL), Richland, WA (United States). Nuclear Sciences Division
  2. Oregon Health & Science Univ., Portland, OR (United States). Center for Radiochemistry Research, Department of Diagnostic Radiology
Publication Date:
Research Org.:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1463331
Alternate Identifier(s):
OSTI ID: 1702371
Report Number(s):
PNNL-SA-134266
Journal ID: ISSN 0021-9673; PII: S002196731830791X
Grant/Contract Number:  
S10-RR017229; AC0576RL01830; AC06-67RLO 1830
Resource Type:
Accepted Manuscript
Journal Name:
Journal of Chromatography
Additional Journal Information:
Journal Volume: 1567; Journal Issue: C; Journal ID: ISSN 0021-9673
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY; 36 MATERIALS SCIENCE; 89Zr; PET imaging; Medical isotope; Laboratory automation; Hydroxamate; Anion exchange; Deferoxamine

Citation Formats

O?Hara, Matthew J., Murray, Nathaniel J., Carter, Jennifer C., Kellogg, Cynthia M., and Link, Jeanne M. Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns. United States: N. p., 2018. Web. doi:10.1016/J.CHROMA.2018.06.035.
O?Hara, Matthew J., Murray, Nathaniel J., Carter, Jennifer C., Kellogg, Cynthia M., & Link, Jeanne M. Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns. United States. https://doi.org/10.1016/J.CHROMA.2018.06.035
O?Hara, Matthew J., Murray, Nathaniel J., Carter, Jennifer C., Kellogg, Cynthia M., and Link, Jeanne M. Tue . "Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns". United States. https://doi.org/10.1016/J.CHROMA.2018.06.035. https://www.osti.gov/servlets/purl/1463331.
@article{osti_1463331,
title = {Tandem column isolation of zirconium-89 from cyclotron bombarded yttrium targets using an automated fluidic platform: Anion exchange to hydroxamate resin columns},
author = {O?Hara, Matthew J. and Murray, Nathaniel J. and Carter, Jennifer C. and Kellogg, Cynthia M. and Link, Jeanne M.},
abstractNote = {The development of a tandem column purification method for the preparation of high-purity 89Zr(IV) oxalate is presented. The primary column was a macroporous strongly basic anion exchange resin on styrene divinylbenzene co-polymer. The secondary column, with an internal volume of 33 μL, was packed with hydroxamate resin. A condition of inverted selectivity was developed, whereby the 89Zr eluent solution for the primary column is equivalent to the 89Zr load solution for the secondary column. The ability to transfer 89Zr from one column to the next allows two sequential column clean-up methods to be performed prior to the final elution of the 89Zr(IV) oxalate. This approach assures delivery of high purity 89Zr product and assures a 89Zr product that is eluted in a substantially smaller volume than is possible when using the traditionally-employed single hydroxamate resin column method. The tandem column purification process has been implemented into a prototype automated fluidic system. The system is configured with on-line gamma detection so column effluents can be monitored in near-real time. The automated method was tested using seven cyclotron bombarded Y foil targets. It was found that 95.1 ± 1.3% of the 89Zr present in the foils was recovered in the secondary column elution fraction. Furthermore, elution peak analysis of several 89Zr elution profile radiochromatograms made possible the determination of 89Zr recovery as a function of volume; a 89Zr product volume that contains 90% of the mean secondary column elution peak can be obtained in 0.29 ± 0.06 mL (representing 86 ± 5% of the 89Zr activity in the target). This product volume represents a significant improvement in radionuclide product concentration over the predominant method used in the field. In addition to the reduced 89Zr product elution volume, titrations of the 89Zr product with deferoxamine mesylate salt across two preparatory methods resulted in mean effective specific activity (ESA) values of 279 and 340 T Bq·mmole-1 and mean bindable metals concentrations ([MB]) of 13.5 and 16.7 nmole·g-1. In conclusion, these ESA and [MB] values infer that the 89Zr(IV) oxalate product resulting from this tandem column isolation method has the highest purity reported to date.},
doi = {10.1016/J.CHROMA.2018.06.035},
journal = {Journal of Chromatography},
number = C,
volume = 1567,
place = {United States},
year = {Tue Jul 24 00:00:00 EDT 2018},
month = {Tue Jul 24 00:00:00 EDT 2018}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 7 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Zirconium-89 Labeled Antibodies: A New Tool for Molecular Imaging in Cancer Patients
journal, January 2014

  • van de Watering, Floor C. J.; Rijpkema, Mark; Perk, Lars
  • BioMed Research International, Vol. 2014
  • DOI: 10.1155/2014/203601

PET Tracers Based on Zirconium-89
journal, April 2011


PET imaging with 89Zr: From radiochemistry to the clinic
journal, January 2013


89Zr Radiochemistry for Positron Emission Tomography
journal, September 2011


The chemistry of PET imaging with zirconium-89
journal, January 2018

  • Dilworth, Jonathan R.; Pascu, Sofia I.
  • Chemical Society Reviews, Vol. 47, Issue 8
  • DOI: 10.1039/C7CS00014F

Production of highly pure no-carrier added 89Zr for the labelling of antibodies with a positron emitter
journal, December 1994

  • Meijs, Wilma E.; Herscheid, Jacobus D. M.; Haisma, Hidde J.
  • Applied Radiation and Isotopes, Vol. 45, Issue 12
  • DOI: 10.1016/0969-8043(94)90029-9

Standardized methods for the production of high specific-activity zirconium-89
journal, October 2009


Semi-automated production of 89 Zr-oxalate/ 89 Zr-chloride and the potential of 89 Zr-chloride in radiopharmaceutical compounding
journal, January 2016


Routine Production of 89Zr Using an Automated Module
journal, July 2013

  • Wooten, A.; Madrid, Evelyn; Schweitzer, Gordon
  • Applied Sciences, Vol. 3, Issue 3
  • DOI: 10.3390/app3030593

Hydroxamate column-based purification of zirconium-89 (89Zr) using an automated fluidic platform
journal, February 2018


Specific activity measurement of 64Cu: A comparison of methods
journal, August 2014


Open letter to journal editors on: International Consensus Radiochemistry Nomenclature Guidelines
journal, February 2018

  • Coenen, Heinz H.; Gee, Antony D.; Adam, Michael
  • Annals of Nuclear Medicine, Vol. 32, Issue 3
  • DOI: 10.1007/s12149-018-1238-z

Purification of radionuclides for nuclear medicine: The multicolumn selectivity inversion generator concept
journal, January 2003


Automated two column generator systems for medical radionuclides
journal, November 2009


Optimized anion exchange column isolation of zirconium-89 (89Zr) from yttrium cyclotron target: Method development and implementation on an automated fluidic platform
journal, April 2018


Recent Advances in Zirconium-89 Chelator Development
journal, March 2018


A simple thick target for production of 89Zr using an 11 MeV cyclotron
journal, April 2017


Evaluation of desferal as a bifunctional chelating agent for labeling antibodies with Zr-89
journal, December 1992

  • Meijs, Wilma E.; Herscheid, Jacobus D. M.; Haisma, Hidde J.
  • International Journal of Radiation Applications and Instrumentation. Part A. Applied Radiation and Isotopes, Vol. 43, Issue 12
  • DOI: 10.1016/0883-2889(92)90170-J

Works referencing / citing this record:

Development of an autonomous solvent extraction system to isolate astatine-211 from dissolved cyclotron bombarded bismuth targets
journal, December 2019

  • O’Hara, Matthew J.; Krzysko, Anthony J.; Hamlin, Donald K.
  • Scientific Reports, Vol. 9, Issue 1
  • DOI: 10.1038/s41598-019-56272-7