Title: Simultaneous 3D MR elastography of the in vivo mouse brain

Abstract

The feasibility of sample interval modulation (SLIM) magnetic resonance elastography (MRE) for the in vivo mouse brain is assessed, and an alternative SLIM-MRE encoding method is introduced. In SLIMMRE, the phase accumulation for each motion direction is encoded simultaneously by varying either the start time of the motion encoding gradient (MEG), SLIM-phase constant (SLIM-PC), or the initial phase of the MEG, SLIM-phase varying (SLIM-PV). SLIM-PC provides gradient moment nulling, but the mutual gradient shift necessitates increased echo time (TE). SLIM-PV requires no increased TE, but exhibits nonuniform flow compensation. Comparison was to conventional MRE using six C57BL/6 mice. For SLIMPC, the Spearman’s rank correlation to conventional MRE for the shear storage and loss modulus images were 80% and 76%, respectively, and likewise for SLIM-PV, 73% and 69%, respectively. The results of the Wilcoxon rank sum test showed that there were no statistically significant differences between the spatially averaged shear moduli derived from conventional-MRE, SLIM-PC, and SLIM-PV acquisitions. Both SLIM approaches were comparable to conventional MRE scans with Spearman’s rank correlation of 69%-80% and with 3 times reduction in scan time. As a result, the SLIM-PC method had the best correlation, and SLIM-PV may be a useful tool in experimental conditions,more » where both measurement time and T2 relaxation is critical.« less

Authors:
 [1];  [2];  [2];  [2]
  1. Univ. of Illinois at Chicago, Chicago, IL (United States); Argonne National Lab. (ANL), Argonne, IL (United States)
  2. Univ. of Illinois at Chicago, Chicago, IL (United States)
Publication Date:
Research Org.:
Argonne National Laboratory (ANL), Argonne, IL (United States)
Sponsoring Org.:
Univ. of Illinois at Chicago, Chicago, IL (United States)
OSTI Identifier:
1434246
Grant/Contract Number:  
AC02-06CH11357
Resource Type:
Accepted Manuscript
Journal Name:
Physics in Medicine and Biology (Online)
Additional Journal Information:
Journal Name: Physics in Medicine and Biology (Online); Journal Volume: 62; Journal Issue: 19; Journal ID: ISSN 1361-6560
Publisher:
IOP Publishing
Country of Publication:
United States
Language:
English
Subject:
60 APPLIED LIFE SCIENCES; MRE; SLIM; elastography; shear modulus; simultaneous; stiffness

Citation Formats

Kearney, Steven P., Majumdar, Shreyan, Royston, Thomas J., and Klatt, Dieter. Simultaneous 3D MR elastography of the in vivo mouse brain. United States: N. p., 2017. Web. doi:10.1088/1361-6560/aa8444.
Kearney, Steven P., Majumdar, Shreyan, Royston, Thomas J., & Klatt, Dieter. Simultaneous 3D MR elastography of the in vivo mouse brain. United States. https://doi.org/10.1088/1361-6560/aa8444
Kearney, Steven P., Majumdar, Shreyan, Royston, Thomas J., and Klatt, Dieter. Fri . "Simultaneous 3D MR elastography of the in vivo mouse brain". United States. https://doi.org/10.1088/1361-6560/aa8444. https://www.osti.gov/servlets/purl/1434246.
@article{osti_1434246,
title = {Simultaneous 3D MR elastography of the in vivo mouse brain},
author = {Kearney, Steven P. and Majumdar, Shreyan and Royston, Thomas J. and Klatt, Dieter},
abstractNote = {The feasibility of sample interval modulation (SLIM) magnetic resonance elastography (MRE) for the in vivo mouse brain is assessed, and an alternative SLIM-MRE encoding method is introduced. In SLIMMRE, the phase accumulation for each motion direction is encoded simultaneously by varying either the start time of the motion encoding gradient (MEG), SLIM-phase constant (SLIM-PC), or the initial phase of the MEG, SLIM-phase varying (SLIM-PV). SLIM-PC provides gradient moment nulling, but the mutual gradient shift necessitates increased echo time (TE). SLIM-PV requires no increased TE, but exhibits nonuniform flow compensation. Comparison was to conventional MRE using six C57BL/6 mice. For SLIMPC, the Spearman’s rank correlation to conventional MRE for the shear storage and loss modulus images were 80% and 76%, respectively, and likewise for SLIM-PV, 73% and 69%, respectively. The results of the Wilcoxon rank sum test showed that there were no statistically significant differences between the spatially averaged shear moduli derived from conventional-MRE, SLIM-PC, and SLIM-PV acquisitions. Both SLIM approaches were comparable to conventional MRE scans with Spearman’s rank correlation of 69%-80% and with 3 times reduction in scan time. As a result, the SLIM-PC method had the best correlation, and SLIM-PV may be a useful tool in experimental conditions, where both measurement time and T2 relaxation is critical.},
doi = {10.1088/1361-6560/aa8444},
journal = {Physics in Medicine and Biology (Online)},
number = 19,
volume = 62,
place = {United States},
year = {Fri Sep 15 00:00:00 EDT 2017},
month = {Fri Sep 15 00:00:00 EDT 2017}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 9 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Assessment of liver viscoelasticity using multifrequency MR elastography
journal, August 2008

  • Asbach, Patrick; Klatt, Dieter; Hamhaber, Uwe
  • Magnetic Resonance in Medicine, Vol. 60, Issue 2
  • DOI: 10.1002/mrm.21636

Concomitant gradient terms in phase contrast MR: Analysis and correction
journal, February 1998

  • Bernstein, Mat A.; Zhou, Xiaohong Joe; Polzin, Jason A.
  • Magnetic Resonance in Medicine, Vol. 39, Issue 2
  • DOI: 10.1002/mrm.1910390218

Long-Term In Vivo Imaging of Viscoelastic Properties of the Mouse Brain after Controlled Cortical Impact
journal, September 2013

  • Boulet, Thomas; Kelso, Matthew L.; Othman, Shadi F.
  • Journal of Neurotrauma, Vol. 30, Issue 17
  • DOI: 10.1089/neu.2012.2788

Frequency-dependent viscoelastic parameters of mouse brain tissue estimated by MR elastography
journal, March 2011


Measurement of signal-to-noise ratios in MR images: Influence of multichannel coils, parallel imaging, and reconstruction filters
journal, January 2007

  • Dietrich, Olaf; Raya, José G.; Reeder, Scott B.
  • Journal of Magnetic Resonance Imaging, Vol. 26, Issue 2
  • DOI: 10.1002/jmri.20969

Cardiac Magnetic Resonance Elastography: Initial Results
journal, January 2008


Alteration of brain viscoelasticity after shunt treatment in normal pressure hydrocephalus
journal, May 2011

  • Freimann, Florian Baptist; Streitberger, Kaspar-Josche; Klatt, Dieter
  • Neuroradiology, Vol. 54, Issue 3
  • DOI: 10.1007/s00234-011-0871-1

Magnetic resonance elastography in the liver at 3 Tesla using a second harmonic approach: 3T Liver MRE Using a Second Harmonic Approach
journal, May 2009

  • Herzka, D. A.; Kotys, M. S.; Sinkus, R.
  • Magnetic Resonance in Medicine, Vol. 62, Issue 2
  • DOI: 10.1002/mrm.21956

Simultaneous, multidirectional acquisition of displacement fields in magnetic resonance elastography of the in vivo human brain: SLIM-MRE of in Vivo Human Brain
journal, November 2014

  • Klatt, Dieter; Johnson, Curtis L.; Magin, Richard L.
  • Journal of Magnetic Resonance Imaging, Vol. 42, Issue 2
  • DOI: 10.1002/jmri.24806

Sample interval modulation for the simultaneous acquisition of displacement vector data in magnetic resonance elastography: theory and application
journal, November 2013


A feasibility study of MR elastography in the diagnosis of prostate cancer at 3.0T
journal, April 2011


Magnetic resonance elastography: Non-invasive mapping of tissue elasticity
journal, December 2001


Magnetic resonance elastography: A review
journal, June 2010

  • Mariappan, Yogesh K.; Glaser, Kevin J.; Ehman, Richard L.
  • Clinical Anatomy, Vol. 23, Issue 5
  • DOI: 10.1002/ca.21006

MR elastography of human lung parenchyma: Technical development, theoretical modeling and in vivo validation
journal, May 2011

  • Mariappan, Yogesh K.; Glaser, Kevin J.; Hubmayr, Rolf D.
  • Journal of Magnetic Resonance Imaging, Vol. 33, Issue 6
  • DOI: 10.1002/jmri.22550

Suitability of poroelastic and viscoelastic mechanical models for high and low frequency MR elastography: Poroelastic and viscoelastic models for MRE
journal, January 2015

  • McGarry, M. D. J.; Johnson, C. L.; Sutton, B. P.
  • Medical Physics, Vol. 42, Issue 2
  • DOI: 10.1118/1.4905048

Multiresolution MR elastography using nonlinear inversion: Multiresolution MR elastography using nonlinear inversion
journal, October 2012

  • McGarry, M. D. J.; Van Houten, E. E. W.; Johnson, C. L.
  • Medical Physics, Vol. 39, Issue 10
  • DOI: 10.1118/1.4754649

Magnetic resonance elastography of the brain in a mouse model of Alzheimer's disease: initial results
journal, May 2012

  • Murphy, Matthew C.; Curran, Geoffrey L.; Glaser, Kevin J.
  • Magnetic Resonance Imaging, Vol. 30, Issue 4
  • DOI: 10.1016/j.mri.2011.12.019

Decreased brain stiffness in Alzheimer's disease determined by magnetic resonance elastography
journal, July 2011

  • Murphy, Matthew C.; Huston, John; Jack, Clifford R.
  • Journal of Magnetic Resonance Imaging, Vol. 34, Issue 3
  • DOI: 10.1002/jmri.22707

Magnetic resonance elastography by direct visualization of propagating acoustic strain waves
journal, September 1995


A framework for optimization-based design of motion encoding in magnetic resonance elastography: Optimization-Based Design of Motion Encoding in MRE
journal, May 2014

  • Nir, Guy; Sahebjavaher, Ramin S.; Sinkus, Ralph
  • Magnetic Resonance in Medicine, Vol. 73, Issue 4
  • DOI: 10.1002/mrm.25280

Fractional encoding of harmonic motions in MR elastography
journal, January 2007

  • Rump, Jens; Klatt, Dieter; Braun, Jürgen
  • Magnetic Resonance in Medicine, Vol. 57, Issue 2
  • DOI: 10.1002/mrm.21152

Non-invasive measurement of brain viscoelasticity using magnetic resonance elastography
journal, January 2008

  • Sack, Ingolf; Beierbach, Bernd; Hamhaber, Uwe
  • NMR in Biomedicine, Vol. 21, Issue 3
  • DOI: 10.1002/nbm.1189

Demyelination reduces brain parenchymal stiffness quantified in vivo by magnetic resonance elastography
journal, April 2012

  • Schregel, K.; Wuerfel nee Tysiak, E.; Garteiser, P.
  • Proceedings of the National Academy of Sciences, Vol. 109, Issue 17
  • DOI: 10.1073/pnas.1200151109

Feasibility of using 3D MR elastography to determine pancreatic stiffness in healthy volunteers: 3D MRE of the Pancreas
journal, February 2014

  • Shi, Yu; Glaser, Kevin J.; Venkatesh, Sudhakar K.
  • Journal of Magnetic Resonance Imaging, Vol. 41, Issue 2
  • DOI: 10.1002/jmri.24572

Viscoelastic shear properties of in vivo breast lesions measured by MR elastography
journal, February 2005


In vivo viscoelastic properties of the brain in normal pressure hydrocephalus
journal, January 2010

  • Streitberger, Kaspar-Josche; Wiener, Edzard; Hoffmann, Jan
  • NMR in Biomedicine
  • DOI: 10.1002/nbm.1602

MR Elastography of Liver Tumors: Preliminary Results
journal, June 2008

  • Venkatesh, Sudhakar K.; Yin, Meng; Glockner, James F.
  • American Journal of Roentgenology, Vol. 190, Issue 6
  • DOI: 10.2214/AJR.07.3123

MR-elastography reveals degradation of tissue integrity in multiple sclerosis
journal, February 2010


Assessment of Hepatic Fibrosis With Magnetic Resonance Elastography
journal, October 2007

  • Yin, Meng; Talwalkar, Jayant A.; Glaser, Kevin J.
  • Clinical Gastroenterology and Hepatology, Vol. 5, Issue 10
  • DOI: 10.1016/j.cgh.2007.06.012

Simultaneous MR elastography and diffusion acquisitions: Diffusion-MRE (dMRE): Simultaneous MRE and Diffusion Acquisitions
journal, March 2014

  • Yin, Ziying; Magin, Richard L.; Klatt, Dieter
  • Magnetic Resonance in Medicine, Vol. 71, Issue 5
  • DOI: 10.1002/mrm.25180

Works referencing / citing this record:

The apparent mechanical effect of isolated amyloid‐β and α‐synuclein aggregates revealed by multi‐frequency MRE
journal, November 2019

  • Bigot, Mathilde; Chauveau, Fabien; Amaz, Camille
  • NMR in Biomedicine, Vol. 33, Issue 1
  • DOI: 10.1002/nbm.4174

Simultaneous multislice rapid magnetic resonance elastography of the liver
journal, January 2020

  • Majeed, Waqas; Kalra, Prateek; Kolipaka, Arunark
  • NMR in Biomedicine, Vol. 33, Issue 4
  • DOI: 10.1002/nbm.4252