DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit

Abstract

We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.

Authors:
ORCiD logo [1];  [2];  [2];  [3];  [4];  [5];  [6];  [7];  [8];  [9]
  1. Ton Duc Thang University, Ho Chi Minh City (Vietnam). Division of Nuclear Physics and Faculty of Applied Sciences; Univ. Bordeaux, CENBG, Gradignan (France); CNRS, IN2P3, CENBG, Gradignan (France)
  2. Princeton Univ., NJ (United States). Department of Physics
  3. Ecoanalytica, Moscow (Russia); Geant4 Associates International Ltd, Hebden Bridge (United Kingdom)
  4. SWHARD srl, Genova (Italy)
  5. Queen's University Belfast, Northern Ireland (United Kingdom). School of Mathematics and Physics
  6. Universidade Estadual de Campinas, SP (Brazil). Instituto de Fisica Gleb Wataghin
  7. Universite Saint Joseph, Beirut (Lebanon). Faculty of Sciences, Department of Physics
  8. Univ. of Notre Dame, IN (United States). Notre Dame Radiation Laboratory
  9. Ton Duc Thang University, Ho Chi Minh City (Vietnam). Division of Nuclear Physics and Faculty of Applied Sciences
Publication Date:
Research Org.:
Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1426131
Report Number(s):
LLNL-JRNL-737989
Journal ID: ISSN 0168-583X; TRN: US1802224
Grant/Contract Number:  
AC52-07NA27344
Resource Type:
Accepted Manuscript
Journal Name:
Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms
Additional Journal Information:
Journal Volume: 372; Journal Issue: C; Journal ID: ISSN 0168-583X
Publisher:
Elsevier
Country of Publication:
United States
Language:
English
Subject:
74 ATOMIC AND MOLECULAR PHYSICS; 46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; Geant4; Auger electrons; Monte Carlo; Electromagnetic interactions

Citation Formats

Incerti, S., Suerfu, B., Xu, J., Ivantchenko, V., Mantero, A., Brown, J. M. C., Bernal, M. A., Francis, Z., Karamitros, M., and Tran, H. N. Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit. United States: N. p., 2016. Web. doi:10.1016/j.nimb.2016.02.005.
Incerti, S., Suerfu, B., Xu, J., Ivantchenko, V., Mantero, A., Brown, J. M. C., Bernal, M. A., Francis, Z., Karamitros, M., & Tran, H. N. Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit. United States. https://doi.org/10.1016/j.nimb.2016.02.005
Incerti, S., Suerfu, B., Xu, J., Ivantchenko, V., Mantero, A., Brown, J. M. C., Bernal, M. A., Francis, Z., Karamitros, M., and Tran, H. N. Tue . "Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit". United States. https://doi.org/10.1016/j.nimb.2016.02.005. https://www.osti.gov/servlets/purl/1426131.
@article{osti_1426131,
title = {Simulation of Auger electron emission from nanometer-size gold targets using the Geant4 Monte Carlo simulation toolkit},
author = {Incerti, S. and Suerfu, B. and Xu, J. and Ivantchenko, V. and Mantero, A. and Brown, J. M. C. and Bernal, M. A. and Francis, Z. and Karamitros, M. and Tran, H. N.},
abstractNote = {We report that a revised atomic deexcitation framework for the Geant4 general purpose Monte Carlo toolkit capable of simulating full Auger deexcitation cascades was implemented in June 2015 release (version 10.2 Beta). An overview of this refined framework and testing of its capabilities is presented for the irradiation of gold nanoparticles (NP) with keV photon and MeV proton beams. The resultant energy spectra of secondary particles created within and that escape the NP are analyzed and discussed. It is anticipated that this new functionality will improve and increase the use of Geant4 in the medical physics, radiobiology, nanomedicine research and other low energy physics fields.},
doi = {10.1016/j.nimb.2016.02.005},
journal = {Nuclear Instruments and Methods in Physics Research. Section B, Beam Interactions with Materials and Atoms},
number = C,
volume = 372,
place = {United States},
year = {Tue Feb 16 00:00:00 EST 2016},
month = {Tue Feb 16 00:00:00 EST 2016}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 42 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Geant4—a simulation toolkit
journal, July 2003

  • Agostinelli, S.; Allison, J.; Amako, K.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 506, Issue 3
  • DOI: 10.1016/S0168-9002(03)01368-8

Geant4 developments and applications
journal, February 2006

  • Allison, J.; Amako, K.; Apostolakis, J.
  • IEEE Transactions on Nuclear Science, Vol. 53, Issue 1
  • DOI: 10.1109/TNS.2006.869826

Recent Improvements in Geant4 Electromagnetic Physics Models and Interfaces
journal, January 2011

  • Ivanchenko, Vladimir; Apostolakis, John; Bagulya, Alexander
  • Progress in Nuclear Science and Technology, Vol. 2, Issue 0
  • DOI: 10.15669/pnst.2.898

PIXE simulation in Geant4
journal, March 2011

  • Mantero, A.; Ben Abdelouahed, H.; Champion, C.
  • X-Ray Spectrometry, Vol. 40, Issue 3
  • DOI: 10.1002/xrs.1301

A comparison between Geant4 PIXE simulations and experimental data for standard reference samples
journal, December 2013

  • Francis, Z.; El Bast, M.; El Haddad, R.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 316
  • DOI: 10.1016/j.nimb.2013.08.006

Comparison of experimental proton-induced fluorescence spectra for a selection of thin high-Z samples with Geant4 Monte Carlo simulations
journal, September 2015

  • Incerti, S.; Barberet, Ph.; Dévès, G.
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 358
  • DOI: 10.1016/j.nimb.2015.06.029

Polynomial approximation to universal ionisation cross-sections of K and L shells induced by H and He ion beams
journal, March 2011

  • Taborda, A.; Chaves, P. C.; Reis, M. A.
  • X-Ray Spectrometry, Vol. 40, Issue 3
  • DOI: 10.1002/xrs.1305

Polynomial approximation to universal M-shell ionisation cross-sections induced by H + and He 2+ ions: Universal M-shell ionisation cross-sections
journal, April 2013

  • Taborda, A.; Chaves, P. C.; Carvalho, M. L.
  • X-Ray Spectrometry, Vol. 42, Issue 4
  • DOI: 10.1002/xrs.2483

Nanop: An x-ray to gold nanoparticle electron and photon emission software
journal, August 2015


Works referencing / citing this record:

Physical Radiation Enhancement Effects Around Clinically Relevant Clusters of Nanoagents in Biological Systems
journal, May 2019


Microdosimetry of electrons in liquid water using the low-energy models of Geant4
journal, July 2017

  • Kyriakou, I.; Emfietzoglou, D.; Ivanchenko, V.
  • Journal of Applied Physics, Vol. 122, Issue 2
  • DOI: 10.1063/1.4992076

Track structure simulations of proximity functions in liquid water using the Geant4-DNA toolkit
journal, March 2019

  • Incerti, S.; Kyriakou, I.; Bordage, M. C.
  • Journal of Applied Physics, Vol. 125, Issue 10
  • DOI: 10.1063/1.5083208

Absorbed dose evaluation of Auger electron-emitting radionuclides: impact of input decay spectra on dose point kernels and S -values
journal, February 2017

  • Falzone, Nadia; Lee, Boon Q.; Fernández-Varea, José M.
  • Physics in Medicine and Biology, Vol. 62, Issue 6
  • DOI: 10.1088/1361-6560/aa5aa4

Feasibility study of Fe 3 O 4 /TaO x nanoparticles as a radiosensitizer for proton therapy
journal, June 2018

  • Ahn, Sang Hee; Lee, Nohyun; Choi, Changhoon
  • Physics in Medicine & Biology, Vol. 63, Issue 11
  • DOI: 10.1088/1361-6560/aac27b

Radio-enhancement by gold nanoparticles and their impact on water radiolysis for x-ray, proton and carbon-ion beams
journal, August 2019

  • Rudek, Benedikt; McNamara, Aimee; Ramos-Méndez, Jose
  • Physics in Medicine & Biology, Vol. 64, Issue 17
  • DOI: 10.1088/1361-6560/ab314c

Determining dose enhancement factors of high- Z nanoparticles from simulations where lateral secondary particle disequilibrium exists
journal, August 2019

  • Rabus, Hans; Gargioni, Elisabetta; Li, Wei Bo
  • Physics in Medicine & Biology, Vol. 64, Issue 15
  • DOI: 10.1088/1361-6560/ab31d4

Geant4 interaction model comparison for dose deposition from gold nanoparticles under proton irradiation
journal, April 2017

  • Sotiropoulos, M.; Taylor, M. J.; Henthorn, N. T.
  • Biomedical Physics & Engineering Express, Vol. 3, Issue 2
  • DOI: 10.1088/2057-1976/aa69cc

Evaluation of dose point kernel rescaling methods for nanoscale dose estimation around gold nanoparticles using Geant4 Monte Carlo simulations
journal, March 2019


Physical Radiation Enhancement Effects Around Clinically Relevant Clusters of Nanoagents in Biological Systems
journal, May 2019