DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy

Abstract

A sensor system based on a continuous wave, external-cavity quantum-cascade laser (CW EC-QCL) was demonstrated for simultaneous detection of atmospheric H2O, HDO, N2O and CH4 using a compact, dense pattern multi-pass gas cell with an effective path-length of 57.6 m. The EC-QCL with a mode-hop-free spectral range of 1225-1285 cm-1 operating at similar to 7.8 mu m was scanned covering four neighboring absorption lines, for H2O at 1281.161 cm-1, HDO at 1281.455 cm-1, N2O at 1281.53 cm-1 and CH4 at 1281.61 cm-1. A first-harmonic-normalized wavelength modulation spectroscopy with second-harmonic detection (WMS-2f/1f) strategy was employed for data processing. An Allan-Werle deviation analysis indicated that minimum detection limits of 1.77 ppmv for H2O, 3.92 ppbv for HDO, 1.43 ppbv for N2O, and 2.2 ppbv for CH4 were achieved with integration times of 50-s, 50-s, 100-s and 129-s, respectively. In conclusion, experimental measurements of ambient air are also reported.

Authors:
 [1];  [2];  [2];  [3]
  1. Rice Univ., Houston, TX (United States). Dept. of Electrical and Computer Engineering; Wuhan Univ., Wuhan (China). School of Electronic Information
  2. Rice Univ., Houston, TX (United States). Dept. of Civil and Environmental Engineering
  3. Rice Univ., Houston, TX (United States). Dept. of Electrical and Computer Engineering
Publication Date:
Research Org.:
Rice Univ., Houston, TX (United States)
Sponsoring Org.:
USDOE Advanced Research Projects Agency - Energy (ARPA-E)
OSTI Identifier:
1286129
Grant/Contract Number:  
AR0000545; AR0000547
Resource Type:
Accepted Manuscript
Journal Name:
Optics Express
Additional Journal Information:
Journal Volume: 24; Journal Issue: 10; Journal ID: ISSN 1094-4087
Publisher:
Optical Society of America (OSA)
Country of Publication:
United States
Language:
English
Subject:
37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CHEMISTRY; wavelength-modulation-spectroscopy; quantum-cascade laser; atmospheric nitrous-oxide; trace-gas detection; formaldehyde detection; water-vapor; methane; temperature; cell

Citation Formats

Yu, Yajun, Sanchez, Nancy P., Griffin, Robert J., and Tittel, Frank K. CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy. United States: N. p., 2016. Web. doi:10.1364/OE.24.010391.
Yu, Yajun, Sanchez, Nancy P., Griffin, Robert J., & Tittel, Frank K. CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy. United States. https://doi.org/10.1364/OE.24.010391
Yu, Yajun, Sanchez, Nancy P., Griffin, Robert J., and Tittel, Frank K. Tue . "CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy". United States. https://doi.org/10.1364/OE.24.010391. https://www.osti.gov/servlets/purl/1286129.
@article{osti_1286129,
title = {CW EC-QCL-based sensor for simultaneous detection of H2O, HDO, N2O and CH4 using multi-pass absorption spectroscopy},
author = {Yu, Yajun and Sanchez, Nancy P. and Griffin, Robert J. and Tittel, Frank K.},
abstractNote = {A sensor system based on a continuous wave, external-cavity quantum-cascade laser (CW EC-QCL) was demonstrated for simultaneous detection of atmospheric H2O, HDO, N2O and CH4 using a compact, dense pattern multi-pass gas cell with an effective path-length of 57.6 m. The EC-QCL with a mode-hop-free spectral range of 1225-1285 cm-1 operating at similar to 7.8 mu m was scanned covering four neighboring absorption lines, for H2O at 1281.161 cm-1, HDO at 1281.455 cm-1, N2O at 1281.53 cm-1 and CH4 at 1281.61 cm-1. A first-harmonic-normalized wavelength modulation spectroscopy with second-harmonic detection (WMS-2f/1f) strategy was employed for data processing. An Allan-Werle deviation analysis indicated that minimum detection limits of 1.77 ppmv for H2O, 3.92 ppbv for HDO, 1.43 ppbv for N2O, and 2.2 ppbv for CH4 were achieved with integration times of 50-s, 50-s, 100-s and 129-s, respectively. In conclusion, experimental measurements of ambient air are also reported.},
doi = {10.1364/OE.24.010391},
journal = {Optics Express},
number = 10,
volume = 24,
place = {United States},
year = {Tue May 03 00:00:00 EDT 2016},
month = {Tue May 03 00:00:00 EDT 2016}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 51 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Simultaneous atmospheric nitrous oxide, methane and water vapor detection with a single continuous wave quantum cascade laser
journal, January 2015

  • Cao, Yingchun; Sanchez, Nancy P.; Jiang, Wenzhe
  • Optics Express, Vol. 23, Issue 3
  • DOI: 10.1364/OE.23.002121

Non-CO2 greenhouse gases and climate change
journal, August 2011

  • Montzka, S. A.; Dlugokencky, E. J.; Butler, J. H.
  • Nature, Vol. 476, Issue 7358
  • DOI: 10.1038/nature10322

Effective utilization of quantum-cascade distributed-feedback lasers in absorption spectroscopy
journal, January 2000

  • Kosterev, Anatoliy A.; Curl, Robert F.; Tittel, Frank K.
  • Applied Optics, Vol. 39, Issue 24
  • DOI: 10.1364/AO.39.004425

High precision measurements of atmospheric nitrous oxide and methane using thermoelectrically cooled mid-infrared quantum cascade lasers and detectors
journal, December 2004

  • Nelson, David D.; McManus, Barry; Urbanski, Shawn
  • Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, Vol. 60, Issue 14
  • DOI: 10.1016/j.saa.2004.01.033

A compact QCL based methane and nitrous oxide sensor for environmental and medical applications
journal, January 2014

  • Jahjah, Mohammad; Ren, Wei; Stefański, Przemysław
  • The Analyst, Vol. 139, Issue 9
  • DOI: 10.1039/c3an01452e

Direct and wavelength modulation spectroscopy using a cw external cavity quantum cascade laser
journal, May 2009

  • Hancock, G.; van Helden, J. H.; Peverall, R.
  • Applied Physics Letters, Vol. 94, Issue 20
  • DOI: 10.1063/1.3141521

A formaldehyde trace gas sensor based on a thermoelectrically cooled CW-DFB quantum cascade laser
journal, January 2014

  • Li, Jingsong; Parchatka, Uwe; Fischer, Horst
  • Anal. Methods, Vol. 6, Issue 15
  • DOI: 10.1039/C3AY41964A

Single-QCL-based absorption sensor for simultaneous trace-gas detection of CH4 and N2O
journal, April 2014


Widely tunable mode-hop free external cavity quantum cascade laser for high resolution spectroscopic applications
journal, September 2005


Widely tunable mode-hop free external cavity quantum cascade lasers for high resolution spectroscopy and chemical sensing
journal, May 2008


Wavelength-modulation-spectroscopy for real-time, in situ NO detection in combustion gases with a 5.2 μm quantum-cascade laser
journal, November 2011


CW DFB RT diode laser-based sensor for trace-gas detection of ethane using a novel compact multipass gas absorption cell
journal, June 2013


Near-infrared diode laser absorption sensor for rapid measurements of temperature and water vapor in a shock tube
journal, September 2007


The HITRAN2012 molecular spectroscopic database
journal, November 2013

  • Rothman, L. S.; Gordon, I. E.; Babikov, Y.
  • Journal of Quantitative Spectroscopy and Radiative Transfer, Vol. 130, p. 4-50
  • DOI: 10.1016/j.jqsrt.2013.07.002

Extension of wavelength-modulation spectroscopy to large modulation depth for diode laser absorption measurements in high-pressure gases
journal, January 2006

  • Li, Hejie; Rieker, Gregory B.; Liu, Xiang
  • Applied Optics, Vol. 45, Issue 5
  • DOI: 10.1364/AO.45.001052

Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments
journal, January 2009

  • Rieker, Gregory B.; Jeffries, Jay B.; Hanson, Ronald K.
  • Applied Optics, Vol. 48, Issue 29, p. 5546-5560
  • DOI: 10.1364/AO.48.005546

Ambient formaldehyde detection with a laser spectrometer based on difference-frequency generation in PPLN
journal, June 2001


Ground-based remote sensing of HDO/H2O ratio profiles: introduction and validation of an innovative retrieval approach
journal, January 2006

  • Schneider, M.; Hase, F.; Blumenstock, T.
  • Atmospheric Chemistry and Physics, Vol. 6, Issue 12
  • DOI: 10.5194/acp-6-4705-2006

Three decades of global methane sources and sinks
journal, September 2013

  • Kirschke, Stefanie; Bousquet, Philippe; Ciais, Philippe
  • Nature Geoscience, Vol. 6, Issue 10
  • DOI: 10.1038/ngeo1955

Spatial variability of methane: Attributing atmospheric concentrations to emissions
journal, July 2014


Compact CH 4 sensor system based on a continuous-wave, low power consumption, room temperature interband cascade laser
journal, January 2016

  • Dong, Lei; Li, Chunguang; Sanchez, Nancy P.
  • Applied Physics Letters, Vol. 108, Issue 1
  • DOI: 10.1063/1.4939452

Works referencing / citing this record:

Real-time breath gas analysis of CO and CO2 using an EC-QCL
journal, April 2017


Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring
journal, May 2017

  • Wu, Hongpeng; Dong, Lei; Zheng, Huadan
  • Nature Communications, Vol. 8, Issue 1
  • DOI: 10.1038/ncomms15331

Simultaneous dual-gas QEPAS detection based on a fundamental and overtone combined vibration of quartz tuning fork
journal, March 2017

  • Wu, Hongpeng; Yin, Xukun; Dong, Lei
  • Applied Physics Letters, Vol. 110, Issue 12
  • DOI: 10.1063/1.4979085

Recent Developments in Modulation Spectroscopy for Methane Detection Based on Tunable Diode Laser
journal, July 2019

  • Wang, Fei; Jia, Shuhai; Wang, Yonglin
  • Applied Sciences, Vol. 9, Issue 14
  • DOI: 10.3390/app9142816