An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS
Abstract
Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.
- Authors:
-
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States). Chemical Sciences Div.
- Publication Date:
- Research Org.:
- Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
- Sponsoring Org.:
- USDOE National Nuclear Security Administration (NNSA)
- OSTI Identifier:
- 1785216
- Alternate Identifier(s):
- OSTI ID: 1779990
- Grant/Contract Number:
- AC05-00OR22725
- Resource Type:
- Accepted Manuscript
- Journal Name:
- Journal of Analytical Atomic Spectrometry
- Additional Journal Information:
- Journal Volume: 36; Journal ID: ISSN 0267-9477
- Publisher:
- Royal Society of Chemistry
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; Uranium; Plutonium; Titanium; MC-ICP-MS; Graphite; Separations
Citation Formats
Metzger, Shalina, Manard, Benjamin, Bostick, Debra, Ticknor, Brian, Rogers, Kayron, Mcbay, Eddie, Glasgow, David, Zirakparvar, N, and Hexel, Cole. An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS. United States: N. p., 2021.
Web. doi:10.1039/D1JA00079A.
Metzger, Shalina, Manard, Benjamin, Bostick, Debra, Ticknor, Brian, Rogers, Kayron, Mcbay, Eddie, Glasgow, David, Zirakparvar, N, & Hexel, Cole. An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS. United States. https://doi.org/10.1039/D1JA00079A
Metzger, Shalina, Manard, Benjamin, Bostick, Debra, Ticknor, Brian, Rogers, Kayron, Mcbay, Eddie, Glasgow, David, Zirakparvar, N, and Hexel, Cole. Mon .
"An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS". United States. https://doi.org/10.1039/D1JA00079A. https://www.osti.gov/servlets/purl/1785216.
@article{osti_1785216,
title = {An approach to separating Pu, U, and Ti from high-purity graphite for isotopic analysis by MC-ICP-MS},
author = {Metzger, Shalina and Manard, Benjamin and Bostick, Debra and Ticknor, Brian and Rogers, Kayron and Mcbay, Eddie and Glasgow, David and Zirakparvar, N and Hexel, Cole},
abstractNote = {Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.},
doi = {10.1039/D1JA00079A},
journal = {Journal of Analytical Atomic Spectrometry},
number = ,
volume = 36,
place = {United States},
year = {Mon Apr 19 00:00:00 EDT 2021},
month = {Mon Apr 19 00:00:00 EDT 2021}
}
Works referenced in this record:
A review on solid phase extraction of actinides and lanthanides with amide based extractants
journal, May 2017
- Ansari, Seraj A.; Mohapatra, Prasanta K.
- Journal of Chromatography A, Vol. 1499
Mass spectrometric determination of impurities in reactor core graphite for radioactive waste composition modelling
journal, January 2010
- Puzas, A.; Remeikis, V.; Ežerinskis, Ž.
- Lithuanian Journal of Physics, Vol. 50, Issue 4
Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry
journal, June 2018
- Metzger, Shalina C.; Ticknor, Brian W.; Rogers, Kayron T.
- Analytical Chemistry, Vol. 90, Issue 15
Combination of 47 Ti and 48 Ti for the determination of highly polydisperse TiO 2 particle size distributions by spICP-MS
journal, January 2019
- Bucher, Guillaume; Auger, François
- Journal of Analytical Atomic Spectrometry, Vol. 34, Issue 7
High precision measurement of titanium isotope ratios by plasma source mass spectrometry
journal, September 2002
- Zhu, X. K.; Makishima, A.; Guo, Y.
- International Journal of Mass Spectrometry, Vol. 220, Issue 1
Exploration of ICP platforms for measuring elemental impurities in uranium ore concentrates
journal, September 2020
- Manard, Benjamin T.; Metzger, Shalina C.; Rogers, Kayron T.
- International Journal of Mass Spectrometry, Vol. 455
Direct atomic absorption spectrometry determination of tin, lead, cadmium and zinc in high-purity graphite with flame furnace atomizer☆
journal, April 2007
- Zacharia, A.; Gucer, S.; Izgi, B.
- Talanta, Vol. 72, Issue 2
Determination of impurities in graphite using synchrotron radiation based X-ray fluorescence spectrometry
journal, October 2017
- Ghosh, M.; Swain, K. K.; Remya Devi, P. S.
- Applied Radiation and Isotopes, Vol. 128
Separation and preconcentration of actinides by extraction chromatography using a supported liquid anion exchanger: application to the characterization of high-level nuclear waste solutions
journal, June 1995
- Horwitz, E. Philip; Dietz, Mark L.; Chiarizia, Renato
- Analytica Chimica Acta, Vol. 310, Issue 1
Determination of impurity elements in graphite by acid decomposition–inductively coupled plasma atomic emission spectrometry
journal, January 1996
- Watanabe, Kazuo; Inagawa, Jun
- The Analyst, Vol. 121, Issue 5
Pure graphite as a reference material for the determination of trace elements — an interlaboratory collaborative study
journal, February 1997
- Bögershausen, W.; Cicciarelli, R.; Gercken, B.
- Fresenius Journal of Analytical Chemistry, Vol. 357, Issue 3
Accurate and precise determination of isotopic ratios by MC-ICP-MS: A review
journal, November 2009
- Yang, Lu
- Mass Spectrometry Reviews, Vol. 28, Issue 6
Uranium isotope analysis by MC-ICP-MS in sub-ng sized samples
journal, January 2016
- Boulyga, Sergei F.; Koepf, Andreas; Konegger-Kappel, Stefanie
- Journal of Analytical Atomic Spectrometry, Vol. 31, Issue 11
Determination of concentrations of trace elements in nuclear grade graphite by charged particle activation analysis
journal, February 2014
- Datta, J.; Chowdhury, D. P.; Verma, R.
- Journal of Radioanalytical and Nuclear Chemistry, Vol. 300, Issue 1
Ultra-precise titanium stable isotope measurements by double-spike high resolution MC-ICP-MS
journal, January 2014
- Millet, Marc-Alban; Dauphas, Nicolas
- Journal of Analytical Atomic Spectrometry, Vol. 29, Issue 8
Microwave-induced combustion method for the determination of trace and ultratrace element impurities in graphite samples by ICP-OES and ICP-MS
journal, November 2015
- Cruz, Sandra M.; Schmidt, Lucas; Dalla Nora, Flavia M.
- Microchemical Journal, Vol. 123
Thermal ionisation mass spectrometry (TIMS) in nuclear science and technology – a review
journal, January 2016
- Aggarwal, Suresh K.
- Analytical Methods, Vol. 8, Issue 5
Isobaric Spike Method for Absolute Isotopic Ratio Determination by MC-ICP-MS
journal, February 2020
- Shuai, Kang; Li, Weiqiang; Hui, Hejiu
- Analytical Chemistry, Vol. 92, Issue 7
Chemical characterization of graphite by instrumental neutron activation analysis
journal, October 2011
- Shinde, Amol D.; Acharya, R.; Verma, R.
- Journal of Radioanalytical and Nuclear Chemistry, Vol. 294, Issue 3
Separation and preconcentration of uranium from acidic media by extraction chromatography
journal, August 1992
- Horwitz, E. Philip; Dietz, Mark L.; Chiarizia, Renato
- Analytica Chimica Acta, Vol. 266, Issue 1
Trace analysis of high-purity graphite by LA-ICP-MS
journal, July 2001
- Pickhardt, Carola; Becker, Johanna Sabine
- Fresenius' Journal of Analytical Chemistry, Vol. 370, Issue 5
High precision titanium isotope measurements on geological samples by high resolution MC-ICPMS
journal, May 2007
- Leya, Ingo; Schönbächler, Maria; Wiechert, Uwe
- International Journal of Mass Spectrometry, Vol. 262, Issue 3
Laser ablation inductively coupled plasma mass spectrometry for the trace, ultratrace and isotope analysis of long-lived radionuclides in solid samples
journal, October 2000
- Becker, Johanna Sabine; Pickhardt, Carola; Dietze, Hans-Joachim
- International Journal of Mass Spectrometry, Vol. 202, Issue 1-3
Multi-element ion-exchange chromatography and high-precision MC-ICP-MS isotope analysis of Mg and Ti from sub-mm-sized meteorite inclusions
journal, January 2018
- Larsen, K. K.; Wielandt, D.; Bizzarro, M.
- Journal of Analytical Atomic Spectrometry, Vol. 33, Issue 4
Separation of titanium from silicates for isotopic ratio determination using multiple collector ICP-MS
journal, July 2002
- Makishima, Akio; Zhu, Xiang-Kun; Belshaw, Nick S.
- Journal of Analytical Atomic Spectrometry, Vol. 17, Issue 10
Mass spectrometric analysis for nuclear safeguards
journal, January 2015
- Boulyga, Sergei; Konegger-Kappel, Stefanie; Richter, Stephan
- Journal of Analytical Atomic Spectrometry, Vol. 30, Issue 7
Direct Determination of Trace Elements in Graphite Matrices Using Modulated Glow Discharge Atomic Absorption Spectrometry
journal, March 1993
- Pan, Changkang; King, Fred L.
- Applied Spectroscopy, Vol. 47, Issue 3
A new method for MC-ICPMS measurement of titanium isotopic composition: Identification of correlated isotope anomalies in meteorites
journal, January 2011
- Zhang, Junjun; Dauphas, Nicolas; Davis, Andrew M.
- Journal of Analytical Atomic Spectrometry, Vol. 26, Issue 11
Separation of actinides from spent nuclear fuel: A review
journal, November 2016
- Veliscek-Carolan, Jessica
- Journal of Hazardous Materials, Vol. 318
Investigation of Impurities of RBMK Graphite by Different Methods
journal, November 2018
- Plukienė, Rita; Lagzdina, Elena; Juodis, Laurynas
- Radiocarbon, Vol. 60, Issue 6
Isotopic Depletion and Decay Methods and Analysis Capabilities in SCALE
journal, May 2011
- Gauld, Ian C.; Radulescu, Georgeta; Ilas, Germina
- Nuclear Technology, Vol. 174, Issue 2
Optimization of uranium and plutonium separations using TEVA and UTEVA cartridges for MC-ICP-MS analysis of environmental swipe samples
journal, June 2019
- Metzger, Shalina C.; Rogers, Kayron T.; Bostick, Debra A.
- Talanta, Vol. 198
Isotopic compositions of the elements 2013 (IUPAC Technical Report)
journal, March 2016
- Meija, Juris; Coplen, Tyler B.; Berglund, Michael
- Pure and Applied Chemistry, Vol. 88, Issue 3
Graphite as a neutron moderator and reflector material
journal, February 1971
- Baker, D. E.
- Nuclear Engineering and Design, Vol. 14, Issue 3
Critical need for plutonium and uranium isotopic standards with lower uncertainties
journal, January 2016
- Mathew, Kattathu J.; Stanley, Floyd E.; Thomas, Mariam R.
- Analytical Methods, Vol. 8, Issue 40
Analysis of high-purity graphite for trace elements by inductively coupled plasma atomic emission spectrometry after chelating resin preconcentration
journal, February 1983
- Mahanti, Himansu S.; Barnes, Ramon M.
- Analytical Chemistry, Vol. 55, Issue 2
Determination of impurity elements in high purity graphite by inductively coupled plasma atomic emission spectrometry after microwave decomposition
journal, January 2000
- Watanabe, Mitsuyoshi; Narukawa, Akira
- The Analyst, Vol. 125, Issue 6
Titanium isotopes and rare earth patterns in CAIs: Evidence for thermal processing and gas-dust decoupling in the protoplanetary disk
journal, January 2018
- Davis, Andrew M.; Zhang, Junjun; Greber, Nicolas D.
- Geochimica et Cosmochimica Acta, Vol. 221