Title: A 5-μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering

Abstract

Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (CK) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft CK X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.

Authors:
 [1];  [1];  [1];  [1];  [1];  [1]
  1. Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Publication Date:
Research Org.:
Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
OSTI Identifier:
1436156
Alternate Identifier(s):
OSTI ID: 1374227
Grant/Contract Number:  
AC02-05CH11231; SC0011269
Resource Type:
Accepted Manuscript
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 88; Journal Issue: 8; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE

Citation Formats

Andresen, N. C., Denes, P., Goldschmidt, A., Joseph, J., Karcher, A., and Tindall, C. S. A 5-μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering. United States: N. p., 2017. Web. doi:10.1063/1.4997727.
Andresen, N. C., Denes, P., Goldschmidt, A., Joseph, J., Karcher, A., & Tindall, C. S. A 5-μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering. United States. https://doi.org/10.1063/1.4997727
Andresen, N. C., Denes, P., Goldschmidt, A., Joseph, J., Karcher, A., and Tindall, C. S. Tue . "A 5-μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering". United States. https://doi.org/10.1063/1.4997727. https://www.osti.gov/servlets/purl/1436156.
@article{osti_1436156,
title = {A 5-μ m pitch charge-coupled device optimized for resonant inelastic soft X-ray scattering},
author = {Andresen, N. C. and Denes, P. and Goldschmidt, A. and Joseph, J. and Karcher, A. and Tindall, C. S.},
abstractNote = {Here, we have developed a charge-coupled device (CCD) with 5 μm × 45 μm pixels on high-resistivity silicon. The fully depleted 200 μm-thick silicon detector is back-illuminated through a 10 nm-thick in situ doped polysilicon window and is thus highly efficient for soft through > 8 keV hard X-rays. The device described here is a 1.5 megapixel CCD with 2496 × 620 pixels. The pixel and camera geometry was optimized for Resonant Inelastic X-ray Scattering (RIXS) and is particularly advantageous for spectrometers with limited arm lengths. In this article, we describe the device architecture, construction and operation, and its performance during tests at the Advance Light Source (ALS) 8.0.1 RIXS beamline. The improved spectroscopic performance, when compared with a current standard commercial camera, is demonstrated with a ~280 eV (CK) X-ray beam on a graphite sample. Readout noise is typically 3-6 electrons and the point spread function for soft CK X-rays in the 5 μm direction is 4.0 μm ± 0.2 μm. Finally, the measured quantum efficiency of the CCD is greater than 75% in the range from 200 eV to 1 keV.},
doi = {10.1063/1.4997727},
journal = {Review of Scientific Instruments},
number = 8,
volume = 88,
place = {United States},
year = {Tue Aug 08 00:00:00 EDT 2017},
month = {Tue Aug 08 00:00:00 EDT 2017}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 4 works
Citation information provided by
Web of Science

Figures / Tables:

FIG. 1 FIG. 1: CCD architecture. Holes accumulate in and travel through the buried p-channels (in light blue). The polysilicon gate structure provides 3-clock phases ($\varphi$1, $\varphi$2, and $\varphi$3 shown in colors over six of the pixels) that shift charges along the column in opposite directions for adjacent columns. At the fourmore » corners, the pixels’ charges are measured and sub-sequentially discarded. No channel stops are used in order to reduce the pixel width to the minimum.« less

Save / Share:

Works referenced in this record:

Development of low noise, back-side illuminated silicon photodiode arrays
journal, June 1997

  • Holland, S. E.; Wang, N. W.; Moses, W. W.
  • IEEE Transactions on Nuclear Science, Vol. 44, Issue 3
  • DOI: 10.1109/23.603687

NIH Image to ImageJ: 25 years of image analysis
journal, June 2012

  • Schneider, Caroline A.; Rasband, Wayne S.; Eliceiri, Kevin W.
  • Nature Methods, Vol. 9, Issue 7
  • DOI: 10.1038/nmeth.2089

X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92
journal, July 1993

  • Henke, B. L.; Gullikson, E. M.; Davis, J. C.
  • Atomic Data and Nuclear Data Tables, Vol. 54, Issue 2, p. 181-342
  • DOI: 10.1006/adnd.1993.1013

Development of a compact fast CCD camera and resonant soft x-ray scattering endstation for time-resolved pump-probe experiments
journal, July 2011

  • Doering, D.; Chuang, Y. -D.; Andresen, N.
  • Review of Scientific Instruments, Vol. 82, Issue 7
  • DOI: 10.1063/1.3609862

Definition of the Flexible Image Transport System (FITS)
journal, September 2001


Calculations of mean free paths and stopping powers of low energy electrons (⩽ 10 keV) in solids using a statistical model
journal, December 1976

  • Ashley, J. C.; Tung, C. J.; Ritchie, R. H.
  • IEEE Transactions on Nuclear Science, Vol. 23, Issue 6
  • DOI: 10.1109/tns.1976.4328586

Developing a CCD camera with high spatial resolution for RIXS in the soft X-ray range
journal, December 2013

  • Soman, M. R.; Hall, D. J.; Tutt, J. H.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 731
  • DOI: 10.1016/j.nima.2013.04.076