DOE Data Explorer title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates

Abstract

This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation. 1 - St. Louis Park house - St. Louis Park, MN 2 - Edina house - Edina, MN In this second study, the team wished to analyze the before and after air-tightness data from roof only ETMMS retrofits on 1.5-story homes in cold and very cold climates. To identify homes to analyze, we reached out to our national network of energy professionals, home performance contractors, and general contractors who had expressed interest in promoting roof-only External Thermal Moisture Management System (ETMMS) to clients. Five projects by three contractors were submitted for consideration as they were being done to mitigate severe ice dams for homeowners. Only two of the five projects followed a roof only ETMMS protocol. Data from the other three projects, however, were reviewed with the air-tightness data of 250 roof-only, interior-applied energy retrofits on 1.5-story homes provided by three NorthernSTAR industry partners. These data represent homes in the general market as well as homes that were part of the state of Minnesota weatherization program.

Authors:
; ; ;
  1. University of Minnesota - NorthernSTAR Building America Partnership
Publication Date:
Other Number(s):
5179
Research Org.:
DOE Open Energy Data Initiative (OEDI); University of Minnesota - NorthernSTAR Building America Partnership
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Multiple Programs (EE)
Collaborations:
University of Minnesota - NorthernSTAR Building America Partnership
Subject:
Array; BuildingAmerica; Roof Deck Ventilation; adhered applied membrane; air sealing; airtightness; attic insulation; building america; cold; deep energy retrofit; existing home; exterior insulation; residential; roof insulation; single family detached; spray foam insulation; very cold
OSTI Identifier:
2204244
DOI:
https://doi.org/10.25984/2204244

Citation Formats

Jacobson, Rolf, Ojzcyk, Cindy, Mosiman, Garrett, and Murry, T. NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates. United States: N. p., 2016. Web. doi:10.25984/2204244.
Jacobson, Rolf, Ojzcyk, Cindy, Mosiman, Garrett, & Murry, T. NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates. United States. doi:https://doi.org/10.25984/2204244
Jacobson, Rolf, Ojzcyk, Cindy, Mosiman, Garrett, and Murry, T. 2016. "NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates". United States. doi:https://doi.org/10.25984/2204244. https://www.osti.gov/servlets/purl/2204244. Pub date:Wed Apr 27 00:00:00 EDT 2016
@article{osti_2204244,
title = {NorthernSTAR Project Overcoat: Exterior Insulation Strategies for 1.5-Story Roof Applications in Cold Climates},
author = {Jacobson, Rolf and Ojzcyk, Cindy and Mosiman, Garrett and Murry, T},
abstractNote = {This is a repository for all NorthernSTAR Overcoat insulation retrofit projects. Both houses received Overcoat insulation retrofit on roof only, performed by Cocoon Insulation. 1 - St. Louis Park house - St. Louis Park, MN 2 - Edina house - Edina, MN In this second study, the team wished to analyze the before and after air-tightness data from roof only ETMMS retrofits on 1.5-story homes in cold and very cold climates. To identify homes to analyze, we reached out to our national network of energy professionals, home performance contractors, and general contractors who had expressed interest in promoting roof-only External Thermal Moisture Management System (ETMMS) to clients. Five projects by three contractors were submitted for consideration as they were being done to mitigate severe ice dams for homeowners. Only two of the five projects followed a roof only ETMMS protocol. Data from the other three projects, however, were reviewed with the air-tightness data of 250 roof-only, interior-applied energy retrofits on 1.5-story homes provided by three NorthernSTAR industry partners. These data represent homes in the general market as well as homes that were part of the state of Minnesota weatherization program.},
doi = {10.25984/2204244},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 27 00:00:00 EDT 2016},
month = {Wed Apr 27 00:00:00 EDT 2016}
}