Title: Excavationless Exterior Foundation Insulation Field Study - Minnesota

Abstract

The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were originally selected for this field study. One was not ready for retrofit at the time of study and had to be eliminated. The collaborative nature of the one field installation, however, enabled the team to advance the methodology as the work progressed. Improvements to the method of installation and reduction of costs were developed on site. This is a repository for all "excavationless" foundation insulation retrofit projects performed by the NorthernSTAR research team. Minneapolis, MN 55411 - Test house for first NorthernSTAR excavationless foundation insulation retrofit.

Authors:
; ; ;
  1. University of Minnesota - NorthernSTAR Building America Partnership
Publication Date:
Other Number(s):
5178
Research Org.:
DOE Open Energy Data Initiative (OEDI); University of Minnesota - NorthernSTAR Building America Partnership
Sponsoring Org.:
USDOE Office of Energy Efficiency and Renewable Energy (EERE), Multiple Programs (EE)
Collaborations:
University of Minnesota - NorthernSTAR Building America Partnership
Subject:
Array; BuildingAmerica; Hydrovac Excavation Technology; Thermal enclosure; building america; cold; cost effectiveness; excavationless; existing home; foundation insulation; liquid insulating foam; residential; retrofit; single family detached; very cold; waterproofing
OSTI Identifier:
2204245
DOI:
https://doi.org/10.25984/2204245

Citation Formats

Jacobson, Rolf, Schirber, Tom, Ojzcyk, Cindy, and Mosiman, Garrett. Excavationless Exterior Foundation Insulation Field Study - Minnesota. United States: N. p., 2016. Web. doi:10.25984/2204245.
Jacobson, Rolf, Schirber, Tom, Ojzcyk, Cindy, & Mosiman, Garrett. Excavationless Exterior Foundation Insulation Field Study - Minnesota. United States. doi:https://doi.org/10.25984/2204245
Jacobson, Rolf, Schirber, Tom, Ojzcyk, Cindy, and Mosiman, Garrett. 2016. "Excavationless Exterior Foundation Insulation Field Study - Minnesota". United States. doi:https://doi.org/10.25984/2204245. https://www.osti.gov/servlets/purl/2204245. Pub date:Wed Apr 27 00:00:00 EDT 2016
@article{osti_2204245,
title = {Excavationless Exterior Foundation Insulation Field Study - Minnesota},
author = {Jacobson, Rolf and Schirber, Tom and Ojzcyk, Cindy and Mosiman, Garrett},
abstractNote = {The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. Two houses were originally selected for this field study. One was not ready for retrofit at the time of study and had to be eliminated. The collaborative nature of the one field installation, however, enabled the team to advance the methodology as the work progressed. Improvements to the method of installation and reduction of costs were developed on site. This is a repository for all "excavationless" foundation insulation retrofit projects performed by the NorthernSTAR research team. Minneapolis, MN 55411 - Test house for first NorthernSTAR excavationless foundation insulation retrofit.},
doi = {10.25984/2204245},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Wed Apr 27 00:00:00 EDT 2016},
month = {Wed Apr 27 00:00:00 EDT 2016}
}