Application of a quartz crystal microbalance to the study of copper corrosion in acid solution inhibited by triazole-iodide protective films
- Pennsylvania State Univ., University Park, PA (United States). Dept. of Materials Science and Engineering
When one uses one side of a quartz crystal microbalance as the working electrode in electrochemical experiments, mass changes can be monitored continuously with a sensitivity of a few nanograms per square centimeter. In this study the working electrode consisted of electrolytically deposited copper, exposed to 0.1M sodium sulfate at pH 3, open to the atmosphere and in some cases containing H{sub 2}O{sub 2}. Upon addition of one of the inhibitors, benzotriazole (BTA), tolyltriazole (TTA), carboxy-benzotriazole (CBT), or these inhibitors plus potassium iodide, the rate of frequency change decreases markedly. After removal of the inhibitors from the corrosive medium by fast solution exchange there is a marked continuing protective effect of the inhibitor films in the cases of BTA + KI and TTA + KI with the latter being the most stable and protective of all of the films. The results were qualitatively the same in the more corrosive solution containing H{sub 2}O{sub 2}.
- Sponsoring Organization:
- USDOE
- OSTI ID:
- 99607
- Journal Information:
- Journal of the Electrochemical Society, Journal Name: Journal of the Electrochemical Society Journal Issue: 7 Vol. 142; ISSN JESOAN; ISSN 0013-4651
- Country of Publication:
- United States
- Language:
- English
Similar Records
In-situ contact electrical resistance technique for investigating corrosion inhibitor adsorption on copper electrodes
Corrosion inhibition of cobalt with a thin film of Cu-BTA