Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

Journal Article · · Transactions of the American Fisheries Society, 139(3):888-899
DOI:https://doi.org/10.1577/T09-043.1· OSTI ID:982546

This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration was lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
982546
Report Number(s):
PNNL-SA-65378; 400403209
Journal Information:
Transactions of the American Fisheries Society, 139(3):888-899, Journal Name: Transactions of the American Fisheries Society, 139(3):888-899 Journal Issue: 3 Vol. 139; ISSN 0002-8487; ISSN 1548-8659
Country of Publication:
United States
Language:
English

Similar Records

Optimal Suturing Technique and Number of Sutures for Surgical Implantation of Acoustic Transmitters in Juvenile Salmonids
Journal Article · Sun Jan 01 23:00:00 EST 2012 · Transactions of the American Fisheries Society, 141:1-10 · OSTI ID:1033041

Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters
Journal Article · Tue Oct 01 00:00:00 EDT 2013 · Fisheries Research, 147:32-35 · OSTI ID:1092650

Performance Assessment of Suture Type in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters
Technical Report · Thu Feb 26 23:00:00 EST 2009 · OSTI ID:949906