Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Optimal Suturing Technique and Number of Sutures for Surgical Implantation of Acoustic Transmitters in Juvenile Salmonids

Journal Article · · Transactions of the American Fisheries Society, 141:1-10

The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing was performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
1033041
Report Number(s):
PNNL-SA-76729; 400403209
Journal Information:
Transactions of the American Fisheries Society, 141:1-10, Journal Name: Transactions of the American Fisheries Society, 141:1-10 Journal Issue: 1 Vol. 141; ISSN 0002-8487; ISSN TAFSAI
Country of Publication:
United States
Language:
English

Similar Records

Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters
Journal Article · Tue Oct 01 00:00:00 EDT 2013 · Fisheries Research, 147:32-35 · OSTI ID:1092650

Performance Assessment of Suture Type in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters
Technical Report · Thu Feb 26 23:00:00 EST 2009 · OSTI ID:949906

Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters
Journal Article · Sat May 01 00:00:00 EDT 2010 · Transactions of the American Fisheries Society, 139(3):888-899 · OSTI ID:982546