Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Lithographic performance evaluation of a contaminated EUV mask after cleaning

Journal Article · · JVST B
OSTI ID:973695

The effect of surface contamination and subsequent mask surface cleaning on the lithographic performance of a EUV mask is investigated. SEMATECH's Berkeley micro-field exposure tool (MET) printed 40 nm and 50 nm line and space (L/S) patterns are evaluated to compare the performance of a contaminated and cleaned mask to an uncontaminated mask. Since the two EUV masks have distinct absorber architectures, optical imaging models and aerial image calculations were completed to determine any expected differences in performance. Measured and calculated Bossung curves, process windows, and exposure latitudes for the two sets of L/S patterns are compared to determine how the contamination and cleaning impacts the lithographic performance of EUV masks. The observed differences in mask performance are shown to be insignificant, indicating that the cleaning process did not appreciably affect mask performance.

Research Organization:
Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
Sponsoring Organization:
Materials Sciences Division
DOE Contract Number:
AC02-05CH11231
OSTI ID:
973695
Report Number(s):
LBNL-2649E
Journal Information:
JVST B, Journal Name: JVST B
Country of Publication:
United States
Language:
English

Similar Records

Carbon contamination topography analysis of EUV masks
Conference · Thu Mar 11 23:00:00 EST 2010 · OSTI ID:983262

Carbon contamination of extreme ultraviolet (EUV) mask and its effect on imaging
Conference · Sun Feb 01 23:00:00 EST 2009 · OSTI ID:953235

Determining the Critcial Size of EUV Mask Substrate Defects
Journal Article · Wed Feb 27 23:00:00 EST 2008 · International Society for Optical Engineering (SPIE) · OSTI ID:934479