Time resolved deposition measurements in NSTX.
- Oak Ridge National Laboratory, Oak Ridge, TN
- Princeton Plasma Physics Laboratory, Princeton, NJ
Time-resolved measurements of deposition in current tokamaks are crucial to gain a predictive understanding of deposition with a view to mitigating tritium retention and deposition on diagnostic mirrors expected in next-step devices. Two quartz crystal microbalances have been installed on NSTX at a location 0.77 m outside the last closed flux surface. This configuration mimics a typical diagnostic window or mirror. The deposits were analyzed ex-situ and found to be dominantly carbon, oxygen and deuterium. A rear facing quartz crystal recorded deposition of lower sticking probability molecules at 10% of the rate of the front facing one. Time resolved measurements over a 4-week period with 497 discharges, recorded 29.2 {micro}g/cm{sup 2} of deposition, however surprisingly, 15.9 {micro}g/cm{sup 2} of material loss occurred at 7 discharges. The net deposited mass of 13.3 {micro}g/cm{sup 2} matched the mass of 13.5 {micro}g/cm{sup 2} measured independently by ion beam analysis. Monte Carlo modeling suggests that transient processes are likely to dominate the deposition.
- Research Organization:
- Sandia National Laboratories
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 956865
- Report Number(s):
- SAND2004-2694C
- Country of Publication:
- United States
- Language:
- English
Similar Records
Mass changes in NSTX Surface Layers with Li Conditioning as Measured by Quartz Microbalances