Lawrence Livermore National Laboratory?s Book of Minimum Detectable Activity for Direct Measurement of Internally Deposited Radionuclides in Radiation Workers
Lawrence Livermore National Laboratory maintains an in vivo measurement program designed to identify and evaluate the activity of radionuclides deposited in the body. Two types of systems are primarily used for the routine monitoring of radiation workers, the lung counting system and the scanning bed whole body counting system. The lung counting system is comprised of two Canberra ACTII detector sets. Each ACTII set contains two planar germanium detectors with carbon composite end windows optimized to measure low energy photon emitting radionuclides. The ACTII detectors are placed on the upper torso over the lungs for the direct measurement of internally deposited radionuclides in the lungs that emit low energy photons. A correction for the thickness of the chest wall is applied to the efficiency. Because the thickness of the chest wall is a key factor in the measurement of low energy photon emitting radionuclides in the lung, the minimum detectable activity is a function of the chest wall thickness. The scanning bed whole body counting system is comprised of a thin air mattress on top of a carbon fiber bed that slowly scans over four high purity germanium detectors. The scanning system is designed to minimize variations in detected activity due to radionuclide distribution in the body. The scanning bed detection system is typically used for the measurement of internally deposited radionuclides that emit photons above 100 to 200 keV. MDAs have been generated for radionuclides that provide energies above 80 keV since the lowest calibration energy for the system is approximately 86 keV. The following charts and table provide best determination of minimum detectable activity using human subjects as controls for the background contributions. A wide variety of radionuclides are used throughout the laboratory and the following pages represent several of the radionuclides that have been encountered at the Whole Body and Spectroscopy Laboratories within Hazards Control.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 945587
- Report Number(s):
- LLNL-TR-407690
- Country of Publication:
- United States
- Language:
- English
Similar Records
Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium detector counting
The gender-specific chest wall thickness prediction equations for routine measurements of {sup 239}Pu and {sup 241}Am within the lungs using HPGE detectors
Biometric estimation of chest wall thickness of females
Journal Article
·
Fri Oct 31 23:00:00 EST 1997
· Health Physics
·
OSTI ID:585238
The gender-specific chest wall thickness prediction equations for routine measurements of {sup 239}Pu and {sup 241}Am within the lungs using HPGE detectors
Journal Article
·
Thu Feb 29 23:00:00 EST 1996
· Health Physics
·
OSTI ID:369932
Biometric estimation of chest wall thickness of females
Journal Article
·
Sun Sep 01 00:00:00 EDT 1985
· Health Phys.; (United States)
·
OSTI ID:5197632