Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Chest wall thickness measurements of the LLNL and JAERI torso phantoms for germanium detector counting

Journal Article · · Health Physics
;  [1]
  1. Human Monitoring Lab., Ottawa, Ontario (Canada)
The Lawrence Livermore National Laboratory and Japanese Atomic Energy Research Institute torso phantoms were developed to calibrate lung counting systems that are used to estimate plutonium and other radionuclides deposited in the lung. Originally, low energy photon counting systems consisted of phoswich detectors. The average chest wall thicknesses and individual measurement points of the Lawrence Livermore National Laboratory phantom and its overlay plates in the regions covered by these detectors were provided by the manufacturer. Germanium detectors are of a different size and are placed in different locations on the phantom so that the manufacturer`s data are no longer applicable for the locations of the germanium detectors on the phantom. The Human Monitoring Laboratory has re-evaluated the chest wall thickness of both the Lawrence Livermore National Laboratory and Japanese Atomic Energy Research Institute phantoms and their overlay plates for its germanium lung counting system. The measurements were made in the upper right, lower right, upper left, and lower left positions on the phantom`s torso plate above the lungs. The effective chest wall thicknesses (17 keV) for the Lawrence Livermore National Laboratory torso plate are 1.46 cm, 1.43 cm, 1.66 cm, 1.48 cm, respectively. The manufacturer`s quoted average effective chest wall thickness for a pair of phoswich detectors is 1.63 cm. The measured effective chest wall thicknesses (17 keV) for the JAERI`s torso plate are 1.76 cm, 2.15 cm, 1.79 cm, 2.15 cm, respectively. The manufacturer`s quoted average chest wall thickness for an unspecified region of the chest is 1.50 cm. This paper presents effective chest wall thickness data for the phantoms with and without their overlay plates at 17 keV, 60 keV, 200 keV and 1,500 keV. 13 refs., 2 figs., 4 tabs.
Sponsoring Organization:
USDOE
OSTI ID:
585238
Journal Information:
Health Physics, Journal Name: Health Physics Journal Issue: 5 Vol. 73; ISSN HLTPAO; ISSN 0017-9078
Country of Publication:
United States
Language:
English

Similar Records

Chest wall thickness measurements: The alternative approach extended for {sup 241}Am
Journal Article · Fri Jan 31 23:00:00 EST 1997 · Health Physics · OSTI ID:458855

Chest wall thickness measurements for enriched uranium: An alternative approach
Journal Article · Sun May 01 00:00:00 EDT 1994 · Health Physics · OSTI ID:249946

Historical review of lung counting efficiencies for low energy photon emitters
Journal Article · Fri Feb 28 19:00:00 EST 2014 · Health Physics · OSTI ID:1244656