Design review report for ecn 638521 (241-SX-106 cover plate installation)
The design for the cover plates on 241-SX-106 was reviewed on 9/10/98. All comments were resolved to the satisfaction of the reviewers. A design calculation for seismic movement was performed and resulted the a design addition to prevent cover block movement. Also calculations were performed for radiological design and are included. The formal design review has no outstanding action items remaining and supports the use of 2 inch steel cover plates to provide personnel shielding and spray knock down protection (as required by the BIO).
- Research Organization:
- HNF Hanford Site (US)
- Sponsoring Organization:
- US DOE Office of Environmental Management (US)
- DOE Contract Number:
- AC06-96RL13200
- OSTI ID:
- 9430
- Report Number(s):
- HNF--3433--REV0; EW3120071; EW3120071
- Country of Publication:
- United States
- Language:
- English