Design review report, 241-S-102 cover plate review

Technical Report ·
DOI:https://doi.org/10.2172/11260· OSTI ID:11260

The design for the cover plate and lead plate for shielding on 241-S-102 was reviewed on 10/21/98. All Review Comment Record comments were resolved to the satisfaction of the reviewers. Additional comments were taken during the meeting and were also resolved. A design calculation for the Radiological Design Review Screening was presented as criteria for the use of 1 inch lead plate. The review concluded that the use of 2 inch steel plate and 1 inch lead plate provided the required safety function required by HNF-SD-WM-810-001, 5.3.2.20, Basis for Interim Operation. The design was approved with the incorporated comments as recorded on RCR's and meeting minutes.

Research Organization:
HNF Hanford Site (US)
Sponsoring Organization:
US DOE Office of Environmental Management (US)
DOE Contract Number:
AC06-96RL13200
OSTI ID:
11260
Report Number(s):
HNF--3558--REV0; EW3120071; EW3120071
Country of Publication:
United States
Language:
English

Similar Records

Design review report for ecn 638521 (241-SX-106 cover plate installation)
Technical Report · Thu Oct 01 00:00:00 EDT 1998 · OSTI ID:9430

Design Review Report for S and SX Farm Leak Detectors
Technical Report · Thu Jan 27 23:00:00 EST 2000 · OSTI ID:801109

Hazard evaluation for transfer of waste from tank 241-SY-101 to tank 241-SY-102
Technical Report · Thu Feb 11 23:00:00 EST 1999 · OSTI ID:781509