Array of Chemically Etched Fused Silica Emitters for Improving the Sensitivity and Quantitation of Electrospray Ionization Mass Spectrometry

Journal Article · · Analytical Chemistry, 79(11):4192-4198
DOI:https://doi.org/10.1021/ac062417e· OSTI ID:910258
An array of emitters has been developed for increasing the sensitivity of electrospray ionization mass spectrometry (ESI-MS). The linear array consists of 19 chemically etched fused silica capillaries arranged with 500 µm (center-to-center) spacing. The multi-emitter device has a low dead volume to facilitate coupling to capillary liquid chromatography (LC) separations. The high aspect ratio of the emitters enables operation at flow rates as low as 20 nL/min/emitter, effectively extending the benefits of nanoelectrospray to higher flow rate analyses. To accommodate the larger ion current produced by the emitter array, a multi-capillary inlet to the mass spectrometer was also constructed. The inlet, which matched the dimensions of the emitter array, effectively preserved ion transmission efficiency. Standard reserpine solutions of varying concentration were electrosprayed at 1 µL/min using the multi-emitter/multi-inlet combination, and compared to a standard, single emitter configuration. A nine-fold sensitivity enhancement was observed for the multi-emitter relative to the single emitter. A bovine serum albumin tryptic digest was also analyzed and resulted in a sensitivity increase ranging from 2.4 to 12.3-fold for the detected tryptic peptides; the varying response was attributed to reduced ion suppression under the nano-ESI conditions afforded by the emitter array. An equimolar mixture of leucine enkephalin and maltopentaose was studied to verify that ion suppression is indeed reduced for the multi-ESI array relative to a single emitter over a range of flow rates.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
910258
Report Number(s):
PNNL-SA-53247; KP1601010
Journal Information:
Analytical Chemistry, 79(11):4192-4198, Journal Name: Analytical Chemistry, 79(11):4192-4198 Journal Issue: 11 Vol. 79
Country of Publication:
United States
Language:
English

Similar Records

Capillary-Based Multi Nanoelectrospray Emitters: Improvements in Ion Transmission Efficiency and Implementation with Capillary Reversed-Phase LC-ESI-MS
Journal Article · Mon Dec 31 23:00:00 EST 2007 · Analytical Chemistry, 80(1):143-149 · OSTI ID:923231

Improving the Sensitivity of Mass Spectrometry by Using a New Sheath Flow Electrospray Emitter Array at Subambient Pressures
Journal Article · Thu Mar 27 20:00:00 EDT 2014 · Journal of the American Society for Mass Spectrometry · OSTI ID:1166826

Ionization and transmission efficiency in an electrospray ionization-mass spectrometry interface
Journal Article · Sat Sep 01 00:00:00 EDT 2007 · Journal of the American Society for Mass Spectrometry, 18(9):1582-1590 · OSTI ID:914674

Related Subjects