SPEAR3 has two diagnostic beam lines: an x-ray pinhole camera and a visible/UV beam line. The pinhole camera images {approx}8 keV dipole synchrotron radiation (SR) incident on a phosphor screen. The visible beam line delivers conventional optical radiation to an array of cameras and diagnostic elements on a 1x3m optical bench. This paper briefly reviews the pinhole camera system while concentrating more on visible beam line power transmission calculations and streak camera data. Impedance estimates in the nominal optics and bunch length measurements in low-alpha optics are presented.