The SPEAR 3 Diagnostic Beamlines
Conference
·
OSTI ID:877441
SPEAR 3 has two diagnostic beam lines: an x-ray pinhole camera and a visible/UV laboratory. The pinhole camera images {approx}8 keV dipole radiation on a phosphor screen with a remote computer to capture digital images and a parallel video signal to the control room. The visible/UV beam line features an 8 mm high GlidCop ''cold finger'' to remove the x-ray core of the beam. The remaining light is deflected horizontally onto an optical bench where it is focused via reflective (Cassegrain) or refractive optics. The visible beam can be split into branch lines for a variety of experimental applications. This paper describes the experimental set up and projected use of both systems.
- Research Organization:
- Stanford Linear Accelerator Center (SLAC)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76SF00515
- OSTI ID:
- 877441
- Report Number(s):
- SLAC-PUB-11757
- Country of Publication:
- United States
- Language:
- English