Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Experiments for calibration and validation of plasticity and failure material modeling: 304L stainless steel.

Technical Report ·
DOI:https://doi.org/10.2172/901707· OSTI ID:901707
Experimental data for material plasticity and failure model calibration and validation were obtained from 304L stainless steel. Model calibration data were taken from smooth tension, notched tension, and compression tests. Model validation data were provided from experiments using thin-walled tube specimens subjected to path dependent combinations of internal pressure, extension, and torsion.
Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
901707
Report Number(s):
SAND2007-0735
Country of Publication:
United States
Language:
English