Global DC closed orbit correction experiment on the NSLS x-ray ring
In this note are described the global DC closed orbit correction experiments conducted on the X-ray ring at National Synchrotron Light Source (NSLS). The beam response matrix, defined as beam motion at BPM locations per unit kick by corrector magnets, was measured and then inverted using the technique of singular value decomposition (SVD). The product of the inverted matrix and the difference orbit gives the incremental kick strengths necessary to correct the orbit. As a result, the r.m.s. orbit error around the ring was reduced from 208 {mu}m to 61 {mu}m.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 87843
- Report Number(s):
- LS--213; ON: DE95015568
- Country of Publication:
- United States
- Language:
- English