Fermilab's 4.3 MeV electron cooler is based on an electrostatic accelerator, which generates a DC electron beam in an energy recovery mode. Effective cooling of the antiprotons in the Recycler requires that the beam remains stable for hours. While short beam interruptions do not deteriorate the performance of the Recycler ring, the beam may provoke full discharges in the accelerator, which significantly affect the duty factor of the machine as well as the reliability of various components. Although cooling of 8 GeV antiprotons has been successfully achieved, full discharges still occur in the current setup. The paper describes factors leading to full discharges and ways to prevent them.