skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: The design and implementation of the machine protection system for the Fermilab electron cooling facility

Conference ·
OSTI ID:956726

The Fermilab Recycler ring employs an electron cooler to store and cool 8.9-GeV antiprotons. The cooler is based on a 4.3-MV, 0.1-A, DC electrostatic accelerator for which current losses have to remain low ({approx}10{sup -5}) in order to operate reliably. The Machine Protection System (MPS) has been designed to interrupt the beam in a matter of 1-2 {micro}s when losses higher than a safe limit are detected, either in the accelerator itself or in the beam lines. This paper highlights the various diagnostics, electronics and logic that the MPS relies upon to successfully ensure that no damage be sustained to the cooler or the Recycler ring.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-07CH11359
OSTI ID:
956726
Report Number(s):
FERMILAB-CONF-09-237-AD; TRN: US1002111
Country of Publication:
United States
Language:
English

Similar Records

Full discharges in Fermilab's electron cooler
Conference · Thu Sep 01 00:00:00 EDT 2005 · OSTI ID:956726

Full Discharges in Fermilab's Electron Cooler
Journal Article · Mon Mar 20 00:00:00 EST 2006 · AIP Conference Proceedings · OSTI ID:956726

Attainment of Electron Beam Suitable for Medium Energy Electron Cooling
Thesis/Dissertation · Sat Jan 01 00:00:00 EST 2005 · OSTI ID:956726