skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: QUAD FAMILY CENTERING.

Abstract

It is well known that beam position monitors (BPM) utilizing signals from pickup electrodes (PUE) provide good resolution and relative accuracy. The absolute accuracy (i.e. position of the orbit in the vacuum chamber) is not very good due to the various reasons. To overcome the limitation it was suggested to use magnetic centers of quadrupoles for the calibration of the BPM [1]. The proposed method provides accuracy better then 200 microns for centering of the beam position monitors using modulation of the whole quadrupole family.

Authors:
Publication Date:
Research Org.:
Brookhaven National Lab. (BNL), Upton, NY (United States)
Sponsoring Org.:
DOE/SC
OSTI Identifier:
861064
Report Number(s):
BNL-75170-2005-CP
R&D Project: LS-001; KC0204011; TRN: US0600209
DOE Contract Number:  
DE-AC02-98CH10886
Resource Type:
Conference
Resource Relation:
Conference: BEAM INSTRUMENTATION WORKSHOP 2006; FERMILAB, IL; 20060501 through 20060504
Country of Publication:
United States
Language:
English
Subject:
43 PARTICLE ACCELERATORS; BEAM POSITION; CALIBRATION; ELECTRODES; MODULATION; MONITORS; QUADRUPOLES; RESOLUTION; BEAM MONITORS

Citation Formats

PINAYEV, I. QUAD FAMILY CENTERING.. United States: N. p., 2005. Web.
PINAYEV, I. QUAD FAMILY CENTERING.. United States.
PINAYEV, I. Tue . "QUAD FAMILY CENTERING.". United States. https://www.osti.gov/servlets/purl/861064.
@article{osti_861064,
title = {QUAD FAMILY CENTERING.},
author = {PINAYEV, I.},
abstractNote = {It is well known that beam position monitors (BPM) utilizing signals from pickup electrodes (PUE) provide good resolution and relative accuracy. The absolute accuracy (i.e. position of the orbit in the vacuum chamber) is not very good due to the various reasons. To overcome the limitation it was suggested to use magnetic centers of quadrupoles for the calibration of the BPM [1]. The proposed method provides accuracy better then 200 microns for centering of the beam position monitors using modulation of the whole quadrupole family.},
doi = {},
journal = {},
number = ,
volume = ,
place = {United States},
year = {Tue Nov 01 00:00:00 EST 2005},
month = {Tue Nov 01 00:00:00 EST 2005}
}

Conference:
Other availability
Please see Document Availability for additional information on obtaining the full-text document. Library patrons may search WorldCat to identify libraries that hold this conference proceeding.

Save / Share: