It is well known that beam position monitors (BPM) utilizing signals from pickup electrodes (PUE) provide good resolution and relative accuracy. The absolute accuracy (i.e. position of the orbit in the vacuum chamber) is not very good due to the various reasons. To overcome the limitation it was suggested to use magnetic centers of quadrupoles for the calibration of the BPM [1]. The proposed method provides accuracy better then 200 microns for centering of the beam position monitors using modulation of the whole quadrupole family.