Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

QUAD FAMILY CENTERING.

Conference ·
OSTI ID:861064
It is well known that beam position monitors (BPM) utilizing signals from pickup electrodes (PUE) provide good resolution and relative accuracy. The absolute accuracy (i.e. position of the orbit in the vacuum chamber) is not very good due to the various reasons. To overcome the limitation it was suggested to use magnetic centers of quadrupoles for the calibration of the BPM [1]. The proposed method provides accuracy better then 200 microns for centering of the beam position monitors using modulation of the whole quadrupole family.
Research Organization:
BROOKHAVEN NATIONAL LABORATORY
Sponsoring Organization:
DOE/SC
DOE Contract Number:
AC02-98CH10886
OSTI ID:
861064
Report Number(s):
BNL--75170-2005-CP; KC0204011
Country of Publication:
United States
Language:
English

Similar Records

Calibration of the beam-position monitor system for the SLAC PEP-II B factory
Conference · Sun Jun 01 00:00:00 EDT 1997 · OSTI ID:525015

Beam-Based BPM Alignment
Technical Report · Sun Sep 01 00:00:00 EDT 2002 · OSTI ID:1157294

Offset calibration of the beam position monitor using external means
Conference · Mon Dec 31 23:00:00 EST 1990 · OSTI ID:6061429