Magnetic Modulator Lifetime Tests Using the Sandia Reliability Test-Bed
Conference
·
OSTI ID:8460
- Sandia National Laboratories
Experimental results are presented that provide design guidelines for high repetition rate, long-life pulsed power magnetic modulators. Fault mechanisms that occurred during a series of 32 million shots at 100 pps, with continuous runs of up to 5.7 million shots (~16 hours) on the Dos Lineas magnetic modulator are described. An effort to explain the fault mechanisms and how to avoid them is made. Factors that limit the long life performance of a variety of components including switches, cables and oil are encountered. The high reliability of the magnetic switch technology is demonstrated.
- Research Organization:
- Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC04-94AL85000
- OSTI ID:
- 8460
- Report Number(s):
- SAND99-1571C; ON: DE00008460
- Country of Publication:
- United States
- Language:
- English