Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Magnetic Modulator Lifetime Tests Using the Sandia Reliability Test-Bed

Conference ·
OSTI ID:8460

Experimental results are presented that provide design guidelines for high repetition rate, long-life pulsed power magnetic modulators. Fault mechanisms that occurred during a series of 32 million shots at 100 pps, with continuous runs of up to 5.7 million shots (~16 hours) on the Dos Lineas magnetic modulator are described. An effort to explain the fault mechanisms and how to avoid them is made. Factors that limit the long life performance of a variety of components including switches, cables and oil are encountered. The high reliability of the magnetic switch technology is demonstrated.

Research Organization:
Sandia National Laboratories (SNL), Albuquerque, NM, and Livermore, CA
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
8460
Report Number(s):
SAND99-1571C; ON: DE00008460
Country of Publication:
United States
Language:
English

Similar Records

Status of Repetitive Pulsed Power at Sandia National Laboratories
Conference · Wed Jun 23 00:00:00 EDT 1999 · OSTI ID:8458

Characterization of the RHEPP 1 {mu}s magnetic pulse compression module
Conference · Sun Aug 01 00:00:00 EDT 1993 · OSTI ID:10180181

High average power magnetic modulator for copper lasers [Book Chapter]
Conference · Tue Aug 06 00:00:00 EDT 2002 · Eighth IEEE International Conference on Pulsed Power · OSTI ID:5402016