High average power magnetic modulator for copper lasers [Book Chapter]
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States); Science Research Laboratory, Inc., Somerville, MA (United States)
Magnetic compression circuits show the promise of long life for operation at high average powers and high repetition rates. When the Atomic Vapor Laser Isotope Separation (AVLIS) Program at Lawrence Livermore National Laboratory needed new modulators to drive their higher power copper lasers in the Laser Demonstration Facility (LDF), existing technology using thyratron switched capacitor inversion circuits did not meet the goal for long lifetimes at the required power levels. We have demonstrated that magnetic compression circuits can achieve this goal. Improving thyratron lifetime is achieved by increasing the thyratron conduction time, thereby reducing the effect of cathode depletion. This paper describes a three stage magnetic modulator designed to provide a 60 kV pulse to a copper laser at a 4. 5 kHz repetition rate. This modulator operates at 34 kW input power and has exhibited MTBF of ≈1000 hours when using thyratrons and even longer MTBFs with a series of stack of SCRs for the main switch. Within this paper, the electrical and mechanical designs for the magnetic compression circuits are discussed as are the important performance parameters of lifetime and jitter. Ancillary circuits such as the charge circuit and reset circuit are shown.
- Research Organization:
- Lawrence Livermore National Laboratory (LLNL), Livermore, CA (United States)
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- W-7405-ENG-48
- OSTI ID:
- 5402016
- Report Number(s):
- UCRL-JC--105816; CONF-910640--34; ON: DE91016560; ISBN: 0-7803-0177-3
- Journal Information:
- Eighth IEEE International Conference on Pulsed Power, Journal Name: Eighth IEEE International Conference on Pulsed Power
- Publisher:
- IEEE
- Country of Publication:
- United States
- Language:
- English
Reliable, High Repetition Rate Thyratron Grid Driver Used With A Magnetic Modulator
|
conference | January 1991 |
The use of saturable reactors as discharge devices for pulse generators
|
journal | May 1951 |
Similar Records
Alternator-driven, magnetically switched modulator
Crossatron switch as thyratron replacement in high repetition rate, high average power modulators
Related Subjects
426002* -- Engineering-- Lasers & Masers-- (1990-)
COMPRESSION
ELECTRICAL PROPERTIES
ELECTRON TUBES
ELECTRONIC CIRCUITS
GAS DISCHARGE TUBES
GAS LASERS
ISOTOPE SEPARATION
LASER ISOTOPE SEPARATION
LASERS
MAGNETIC COMPRESSION
MECHANICAL PROPERTIES
METAL VAPOR LASERS
MODULATION
PERFORMANCE
PHYSICAL PROPERTIES
SEPARATION PROCESSES
SPECIFICATIONS
SWITCHING CIRCUITS
THYRATRONS