Resolution Quality and Atom Positions in Sub-Angstrom Electron Microscopy
Conference
·
OSTI ID:842050
- LBNL Library
Ability to determine whether an image peak represents one single atom or several depends on resolution of the HR-(S)TEM. Rayleigh's resolution criterion, an accepted standard in optics, was derived as a means for judging when two image intensity peaks from two sources of light (stars) are distinguishable from a single source. Atom spacings closer than the Rayleigh limit have been resolved in HR-TEM, suggesting that it may be useful to consider other limits, such as the Sparrow resolution criterion. From the viewpoint of the materials scientist, it is important to be able to use the image to determine whether an image feature represents one or more atoms (resolution), and where the atoms (or atom columns) are positioned relative to one another (resolution quality). When atoms and the corresponding image peaks are separated by more than the Rayleigh limit of the HR-(S)TEM, it is possible to adjust imaging parameters so that relative peak positions in the image correspond to relative atom positions in the specimen. When atoms are closer than the Rayleigh limit, we must find the relationship of the peak position to the atom position by peak fitting or, if we have a suitable model, by image simulation. Our Rayleigh-Sparrow parameter QRS reveals the ''resolution quality'' of a microscope image. QRS values greater than 1 indicate a clearly resolved twin peak, while values between 1 and 0 mean a lower-quality resolution and an image with peaks displaced from the relative atom positions. The depth of the twin-peak minimum can be used to determine the value of QRS and the true separation of the atom peaks that sum to produce the twin peak in the image. The Rayleigh-Sparrow parameter can be used to refine relative atom positions in defect images where atoms are closer than the Rayleigh limit of the HR-(S)TEM, reducing the necessity for full image simulations from large defect models.
- Research Organization:
- Ernest Orlando Lawrence Berkeley National Laboratory, Berkeley, CA (US)
- Sponsoring Organization:
- USDOE Director. Office of Science. Office of Basic Energy Sciences (US)
- DOE Contract Number:
- AC03-76SF00098
- OSTI ID:
- 842050
- Report Number(s):
- LBNL--57524
- Country of Publication:
- United States
- Language:
- English
Similar Records
Resolution Quality and Atom Positions in Sub-?ngstr?m Electron Microscopy
Sub-Angstrom resolution with aberration-corrected TEM: Present and future
Direct Sub-Angstrom Imaging of a Crystal Lattice
Conference
·
Fri Dec 31 23:00:00 EST 2004
·
OSTI ID:1003096
Sub-Angstrom resolution with aberration-corrected TEM: Present and future
Conference
·
Thu Jul 01 00:00:00 EDT 2004
·
OSTI ID:836049
Direct Sub-Angstrom Imaging of a Crystal Lattice
Journal Article
·
Wed Dec 31 23:00:00 EST 2003
· Science
·
OSTI ID:1003086