Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer

Journal Article · · IEEE Transactions on Magnetics
DOI:https://doi.org/10.1109/20.508594· OSTI ID:840626
The 4 GeV/c high resolution spectrometers of the CEBAF experimental Hall A require two mirror imaged superconducting quadrupole magnets of cosine 2thetas; configuration. These magnets, built at Saclay, have the following parameters: 300 mm clear bore, 948 mm magnetic length, quadrupole field gradient 8.5 T/m with a 1 x 10{sup -5} uniformity. The paper gives an overview of the design and describes construction technology and test results: coil dimensions, harmonics content, gradient measurement
Research Organization:
Thomas Jefferson National Accelerator Facility, Newport News, VA (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC05-84ER40150
OSTI ID:
840626
Report Number(s):
CEBAF-PR-96-022; DOE/ER/40150-3441
Journal Information:
IEEE Transactions on Magnetics, Journal Name: IEEE Transactions on Magnetics Journal Issue: 4 Vol. 32; ISSN IEMGAQ; ISSN 0018-9464
Country of Publication:
United States
Language:
English

Similar Records

Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Journal Article · Mon Jul 01 00:00:00 EDT 1996 · IEEE Transactions on Magnetics · OSTI ID:282390

Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Journal Article · Fri Jul 01 00:00:00 EDT 1994 · IEEE Transactions on Magnetics · OSTI ID:840621

Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Conference · Fri Jul 01 00:00:00 EDT 1994 · IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States) · OSTI ID:6450974