Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Journal Article
·
· IEEE Transactions on Magnetics
- CEA-DSM/DAPNIA, Gif-sur-Yvette (France). Service Technique de Cryogenie et de Magnetisme
The 4 GeV/c high resolution spectrometers of the CEBAF experimental Hall A require two mirror imaged superconducting quadrupole magnets of cosine 2{theta} configuration. These magnets, built at Saclay, have the following parameters: 300 mm clear bore, 948 mm magnetic length, quadrupole field gradient 8.5 T/m with a 1 {times} 10{sup {minus}3} uniformity. The paper gives an overview of the design and describes construction technology and test results: coil dimensions, harmonics content, gradient measurement.
- OSTI ID:
- 282390
- Report Number(s):
- CONF-950691--
- Journal Information:
- IEEE Transactions on Magnetics, Journal Name: IEEE Transactions on Magnetics Journal Issue: 4Pt1 Vol. 32; ISSN IEMGAQ; ISSN 0018-9464
- Country of Publication:
- United States
- Language:
- English
Similar Records
Test results of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Journal Article
·
Mon Jul 01 00:00:00 EDT 1996
· IEEE Transactions on Magnetics
·
OSTI ID:840626
Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Conference
·
Fri Jul 01 00:00:00 EDT 1994
· IEEE Transactions on Magnetics (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6450974
Design and manufacture of the Q1 quadrupoles for the CEBAF high resolution spectrometer
Journal Article
·
Fri Jul 01 00:00:00 EDT 1994
· IEEE Transactions on Magnetics
·
OSTI ID:840621