Design Considerations for the LCLS RF Gun
- SLAC
The LCLS rf gun design requires several modifications from existing S-band rf guns. The modifications that have the largest impact on the design of the gun are a dual rf feed and additional cooling capacity for 120 Hz operation. A list of electrical and mechanical specifications have been developed to produce the desired rf field. The simulation code ANSYS was used to study the steady state thermal properties of a 120 Hz gun. It was determined that four cooling channels at appropriate locations could be used to maintain the gun at a nearly constant frequency. The gun body stresses were all at or below the yield strength of Cu except for at the rf apertures. The stress at the apertures is over twice the yield strength and additional work is necessary to reduce the stress and still produce the desired rf coupling coefficient. Only steady state temperatures were calculated and no pulsed heating effects were considered in this study.
- Research Organization:
- Stanford Linear Accelerator Center (SLAC), Menlo Park, CA
- Sponsoring Organization:
- SC
- DOE Contract Number:
- AC02-76SF00515;
- OSTI ID:
- 839679
- Report Number(s):
- SLAC-TN-05-019
- Country of Publication:
- United States
- Language:
- English
Similar Records
RF Design of the LCLS Gun
Reducing the Heat Load on the LCLS 120 Hz RF Gun with RF Pulse Shaping
Design studies for the LCLS 120 Hz RF gun
Technical Report
·
Sun Dec 12 19:00:00 EST 2010
·
OSTI ID:1000384
Reducing the Heat Load on the LCLS 120 Hz RF Gun with RF Pulse Shaping
Technical Report
·
Sun Jan 30 19:00:00 EST 2005
·
OSTI ID:839687
Design studies for the LCLS 120 Hz RF gun
Technical Report
·
Tue Oct 31 23:00:00 EST 2000
·
OSTI ID:773964