Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

GYROTRON POWER BALANCE BASED ON CALORIMETRIC MEASUREMENTS IN THE DIII-D ECH SYSTEM

Conference ·
OSTI ID:823615
OAK-B135 A powerful microwave system operating at the second harmonic of the electron cyclotron frequency on the DIII-D tokamak was upgraded up to six assemblies of 110 GHz gyrotrons in 2003. three Gycom gyrotrons nominally generate 750 kW for 2 s pulses, with the pulse length limit resulting from the peak temperature allowed on the boron nitride rf output window. Three Communications and Power Industries (CPI) gyrotrons with diamond windows have been recently installed and have been tested to 0.9-1.0 MW for 5 s pulses. Heat loading on internal parts of the gyrotrons, the matching optics unit and the dummy loads is measured calorimetrically. This paper discusses the calorimetry system and calorimetric measurements of gyrotron performance.
Research Organization:
GENERAL ATOMICS (US)
Sponsoring Organization:
(US)
DOE Contract Number:
AC03-99ER54463
OSTI ID:
823615
Report Number(s):
GA-A24493
Country of Publication:
United States
Language:
English

Similar Records

PRACTICAL EXERIENCES WITH THE 6 GYROTRON SYSTEM ON THE DIII-D TOKAMAK
Conference · Wed Oct 01 00:00:00 EDT 2003 · OSTI ID:823622

INFRARED MONITORING OF 110GHz GYROTRON WINDOWS AT DIII-D
Conference · Wed May 01 00:00:00 EDT 2002 · OSTI ID:804882

The DIII-D 3 MW, 110 GHz ECH System